Most Fire Alarms Are Installed. Few Are Designed.

An alarm that wasn't designed for your building creates serious gaps

Detectors too far apart fire spreads before activation · Wrong detector type for the area kitchen heat detectors in offices · No cause-and-effect matrix staff don’t know which zone is alarming or where to evacuate.

What We Install

Addressable Systems Exact Location, Every Time

Pinpoints the exact detector or call point that activated. Gives your fire warden and the fire brigade the precise information they need. Standard for medium and large commercial buildings in Ireland.

Conventional Systems Cost-Effective for Smaller Premises

Identifies the zone of activation. Fully compliant with IS 3218. The right solution for smaller commercial buildings where zone-level information is sufficient.

Aspirating Smoke Detection — The Earliest Possible Warning

Detects fire at the earliest invisible stage — before conventional detectors respond. Essential for server rooms, data centres, and high-value storage areas.

Beam Detection — For Large Open Spaces

One beam covers up to 100 metres. The practical, cost-effective solution for warehouses, atria, and large industrial spaces.

Had a fire alarm failure or false alarm that cost you?

We’ll audit your existing system and tell you what’s wrong — free of charge.

What a Properly Designed System Gives You

If your fire alarm has never had a formal commissioning certificate issued, it may not be IS 3218 compliant. Contact us to check.
fire-detection

Frequently Asked Questions

IS 3218 is the Irish standard for fire detection and alarm systems in non-domestic buildings. All commercial fire alarms in Ireland must comply. Non-compliance can invalidate your insurance and result in enforcement action from the fire authority.
Addressable systems identify the exact device that has activated. Conventional systems identify the zone. For most medium and large commercial buildings in Ireland, addressable is the recommended standard.
IS 3218 requires quarterly inspection and testing. We offer contracts covering all required visits with written certificates issued after each one.
Yes. We audit the current system, identify the upgrade path, and advise on whether existing infrastructure can be retained. In many cases it can.
Yes. We serve commercial clients across Dublin, Kildare, Meath, Wicklow, and the wider Leinster region.