Enhancement Request
Once v25.2-IOFreeze is released, we should update to it.
Detailed Description
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/InputRulesFiles/Rules25-1-0-to-25-2-0.md
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/OutputRulesFiles/OutputChanges25-1-0-to-25-2-0.md
Major changes
New additions
-
Site:WaterMainsTemperature: New "Temperature Multiplier" and "Temperature Offset" fields V25.2.0-IOFreeze: SiteWaterMainsTemperature's new fields #5477 -
ZoneHVAC:Baseboard:RadiantConvective:Water,ZoneHVAC:Baseboard:RadiantConvective:Steam,ZoneHVAC:LowTemperatureRadiant:VariableFlow, andZoneHVAC:LowTemperatureRadiant:ConstantFlow: Design Object field is required and referencesRadiantDesignObject- Why doesn't
ZoneHVAC:Baseboard:RadiantConvective:Steam:Designhave a\reference RadiantDesignObject?
- Why doesn't
-
ZoneHVAC:HighTemperatureRadiant: field "Heating Setpoint Temperature Schedule Name" is now required- What's the action here? Update getter/setter and also come up with a schedule to initialize in the ctor?
-
Coil:DX:ASHRAE205:Performance: new object E+ 25.2.0: Wrap Coil:DX:ASHRAE205:Performance #5476 -
Duct:Loss:Conduction,Duct:Loss:Leakage,Duct:Loss:MakeupAir: new objects E+ 25.2.0: Wrap Duct:Loss:Conduction, Duct:Loss:Leakage, Duct:Loss:MakeupAir #5485 -
Coil:Cooling:WaterToAirHeatPump:EquationFit,Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit,Coil:Heating:WaterToAirHeatPump:EquationFit,Coil:Heating:WaterToAirHeatPump:VariableSpeedEquationFit: new "AFNCoilNames" reference for "Name" field V25.2.0-IOFreeze: new AFNCoilNames references #5479- Reference "AFNCoilNames" is already in the IDD for
Coil:Cooling:DX:VariableSpeed,Coil:Heating:DX:VariableSpeed. - Update
children; addgetAirflowNetworkEquivalentDuctandairflowNetworkEquivalentDuctmethods; updateModelStraightComponent.i. - Appears that
Coil:Cooling:DX:TwoSpeed,Coil:Cooling:DX:VariableSpeed,Coil:Heating:DX:VariableSpeed,Coil:Cooling:DX, andCoil:Cooling:DX:SingleSpeed:ThermalStorageneed to be updated/fixed.
- Reference "AFNCoilNames" is already in the IDD for
-
HeatPump:AirToWater:FuelFired:HeatingandHeatPump:AirToWater:FuelFired:Cooling: New "Minimum Unloading Ratio" field V25.2.0-IOFreeze: HeatPumpAirToWaterFuelFired's new fields #5478 -
ExternalInterface:FunctionalMockupUnitExport:To:ScheduleandExternalInterface:FunctionalMockupUnitExport:To:Actuator: field "Initial Value" is now optional V25.2.0-IOFreeze: ExternalInterface's optional Initial Value field #5481 -
EvaporativeFluidCooler:SingleSpeed,EvaporativeFluidCooler:TwoSpeed: default changes for "Design Entering Water Temperature", "Design Entering Air Temperature", "Design Entering Air Wet-bulb Temperature" V25.2.0-IOFreeze: new EvaporativeFluidCooler defaults #5486 -
ZoneHVAC:IdealLoadsAirSystem: new fields "Heating Fuel Efficiency Schedule Name", "Heating Fuel Type", "Cooling Fuel Efficiency Schedule Name", "Cooling Fuel Type" V25.2.0-IOFreeze: new ZoneHVACIdealLoadsAirSystem fields #5487 -
Sizing:Zone,Sizing:System: new fields "Heating Coil Sizing Method" and "Maximum Heating Capacity To Cooling XXX Sizing Ratio" V25.2.0-IOFreeze: new SizingZone and SizingSystem fields #5491 - New "DX Heating Coil Sizing Ratio" field V25.2.0-IOFreeze: new DX Heating Coil Sizing Ratio fields #5492
ZoneHVAC:PackagedTerminalHeatPump,ZoneHVAC:WaterToAirHeatPump,AirLoopHVAC:UnitaryHeatPump:AirToAir,AirLoopHVAC:UnitaryHeatPump:WaterToAir: new fieldAirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed: replaces "Minimum Outdoor Dry-Bulb Temperature for Compressor Operation" field
-
HeatPump:AirToWater: new object Fix #5490 - E+ 25.2.0: Wrap HeatPump:AirToWater #5496- Includes new "Water Loop Type" field for
PlantLoop
- Includes new "Water Loop Type" field for
- New
OutputXXXfieldsOutputControl:Table:Style: "Format Numeric Values"Output:JSON: "Unit Conversion for Tabular Data", "Format Numeric Values for Tabular Data"Output:SQLite: "Format Numeric Values for Tabular Data"
-
ThermalStorage:ChilledWater:StratifiedV25.2.0-IOFreeze: new ThermalStorageChilledWaterStratified default #5495- "Deadband Temperature Difference" changes
- "Nominal Cooling Capacity' autosizable
- Add field "Availability Schedule Name" V25.2.0-IOFreeze: new Availability Schedule Name fields for coils #5498
Coil:XXX:DX:VariableSpeedCoil:XXX:WaterToAirHeatPump:ParameterEstimationCoil:XXX:WaterToAirHeatPump:EquationFitCoil:XXX:WaterToAirHeatPump:VariableSpeedEquationFitCoil:WaterHeating:AirToWaterHeatPump:PumpedCoil:WaterHeating:AirToWaterHeatPump:WrappedCoil:WaterHeating:AirToWaterHeatPump:VariableSpeed
-
ThermalStorage:PCM: new object E+ 25.2.0: Wrap ThermalStorage:PCM #5493 -
ThermalStorage:HotWater:Stratified: new object E+ 25.2.0: Wrap ThermalStorage:HotWater:Stratified #5494 -
GroundHeatExchanger:Vertical:Sizing:Rectangle: new object E+ 25.2.0: Wrap GroundHeatExchanger:Vertical:Sizing:Rectangle #5500 -
OutputControl:Files: new "Output Plant Component Sizing" field New Output Plant Component Sizing field for OutputControl:Files #5511
Minor stuff
-
Coil:Heating:WaterToAirHeatPump:VariableSpeedEquationFit: SpeedReferenceUnitRatedAirFlow to SpeedReferenceUnitRatedAirFlowRate -
Coil:WaterHeating:AirToWaterHeatPump:VariableSpeed: XXXatSpeed to SpeedXXX -
HeatExchanger:Desiccant:BalancedFlow: EconomizerLockout now defaulted to "Yes" -
AirflowNetwork:Distribution:Node: new "Zone" key for ComponentObjectTypeorNodeType -
Boiler:HotWater: NominalCapacity must be greater than zero -
GroundHeatExchanger:System: new "GHE:Vertical:Sizing Object Type" and "GHE:Vertical:Sizing Object Name" fields