Skip to content

Conversation

@joseph-robertson
Copy link
Collaborator

Pull request overview

Pull Request Author

  • Model API Changes / Additions
  • Any new or modified fields have been implemented in the EnergyPlus ForwardTranslator (and ReverseTranslator as appropriate)
  • Model API methods are tested (in src/model/test)
  • EnergyPlus ForwardTranslator Tests (in src/energyplus/Test)
  • If a new object or method, added a test in NREL/OpenStudio-resources: Add Link
  • If needed, added VersionTranslation rules for the objects (src/osversion/VersionTranslator.cpp)
  • Verified that C# bindings built fine on Windows, partial classes used as needed, etc.
  • All new and existing tests passes
  • If methods have been deprecated, update rest of code to use the new methods

Labels:

  • If change to an IDD file, add the label IDDChange
  • If breaking existing API, add the label APIChange
  • If deemed ready, add label Pull Request - Ready for CI so that CI builds your PR

Review Checklist

This will not be exhaustively relevant to every PR.

  • Perform a Code Review on GitHub
  • Code Style, strip trailing whitespace, etc.
  • All related changes have been implemented: model changes, model tests, FT changes, FT tests, VersionTranslation, OS App
  • Labeling is ok
  • If defect, verify by running develop branch and reproducing defect, then running PR and reproducing fix
  • If feature, test running new feature, try creative ways to break it
  • CI status: all green or justified

@joseph-robertson joseph-robertson added Pull Request - Ready for CI This pull request if finalized and is ready for continuous integration verification prior to merge. IDDChange labels Aug 21, 2025
// = {252660024.14000002, 28129.12, 428.19, 360.93, 781.28, 3322324.62, 249308000.0};
// To reduce the deviation, I switched the PTAC/PTHP to a Fan:OnOff with a Always Off Discrete Schedule, but it still behaves slightly differently
SqlResults ep_2510 = {191879399.92, 27905.27, 407.55, 361.09, 776.63, 3328949.38, 188521000.0};
SqlResults ep_2520 = {191879399.92, 27905.27, 407.55, 361.09, 776.63, 3328949.38, 188521000.0};
Copy link
Collaborator Author

@joseph-robertson joseph-robertson Oct 15, 2025

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I'm not sure why (expected or not), but appears sqlFile2.annualTotalCost(FuelType::FuelOil_1).get() has increased from 188521000.0 to 188521400.0. This causes a test failure.

Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Probably related to this? NREL/EnergyPlus#11109

Copy link
Collaborator Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Meaning it was previously 188521400.0 but was being reported as 188521000.0?

Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

That's my guess, yes.

Copy link
Collaborator Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Copy link
Collaborator Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Whoa, now I'm really confused. We got ubuntu back online (and not just windows), and I see the test fails on different lines. Appears the annual total costs may vary by platform???

jmarrec and others added 5 commits October 16, 2025 12:48
AirflowNetwork:Distribution:DuctSizing

Duct:Loss:Conduction
Duct:Loss:Leakage
Duct:Loss:MakeupAir

HeatPump:AirToWater
ThermalStorage:HotWater:Stratified
ThermalStorage:PCM
ThermalStorage:Sizing
Output:Table:ReportPeriod
@@ -63074,7 +64416,57 @@ Output:Table:Annual,
\minimum 0
\maximum 10


Output:Table:ReportPeriod,
Copy link
Collaborator Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Just a note that this is not introduced in E+ v25.2.0.

@joseph-robertson joseph-robertson marked this pull request as ready for review October 16, 2025 22:33
@jmarrec
Copy link
Collaborator

jmarrec commented Oct 20, 2025

I just updated the sql test results per Ubuntu's result, will let CI report on that.

Note that looking at build/resources/energyplus/Office_With_Many_HVAC_Types/eplusout.err, we have some iterations that don't converge etc.

   *************  ** Warning ** CalcDoe2DXCoil: Coil:Cooling:DX:SingleSpeed="COIL COOLING DX SINGLE SPEED 1" - Low condenser dry-bulb temperature error continues...
   *************  **   ~~~   **   This error occurred 538 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************  **   ~~~   **   Max=-0.025000 [C]  Min=-16.400000 [C]
   *************
   *************  ** Warning ** CalcDoe2DXCoil: Coil:Cooling:DX:SingleSpeed="COIL COOLING DX SINGLE SPEED 1" - Full load outlet temperature indicates a possibility of frost/freeze error continues. Outlet air temperature statistics follow:
   *************  **   ~~~   **   This error occurred 3265 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************  **   ~~~   **   Max=1.997726  Min=-12.977307
   *************
   *************  ** Warning ** CalcDoe2DXCoil: Coil:Cooling:DX:SingleSpeed="PTAC 1 SPD DX CLG COIL" - Low condenser dry-bulb temperature error continues...
   *************  **   ~~~   **   This error occurred 1654 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************  **   ~~~   **   Max=-0.025000 [C]  Min=-17.800000 [C]
   *************
   *************  ** Warning ** SimHVAC: Exceeding Maximum iterations for all HVAC loops, during RUN PERIOD 1 continues
   *************  **   ~~~   **   This error occurred 29 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************
   *************  ** Warning ** Enthalpy out of range (PsyTsatFnHPb)
   *************  **   ~~~   **   This error occurred 5244 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************  **   ~~~   **   Max=-42407.194043 J/kg  Min=-64004.585725 J/kg
   *************
   *************  ** Warning ** CalcDoe2DXCoil: Coil:Cooling:DX:SingleSpeed="PTHP 1 SPD DX CLG COIL" - Low condenser dry-bulb temperature error continues...
   *************  **   ~~~   **   This error occurred 5 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************  **   ~~~   **   Max=-2.900000 [C]  Min=-4.450000 [C]
   *************
   *************  ** Warning ** Calculated Humidity Ratio invalid (PsyWFnTdbH)
   *************  **   ~~~   **   This error occurred 564 total times;
   *************  **   ~~~   **   during Warmup 0 times;
   *************  **   ~~~   **   during Sizing 0 times.
   *************  **   ~~~   **   Max=-0.000272 []  Min=-0.008218 []

V25.2.0-IOFreeze: SiteWaterMainsTemperature's new fields
V25.2.0-IOFreeze: ExternalInterface's optional Initial Value field
@ci-commercialbuildings
Copy link
Collaborator

ci-commercialbuildings commented Oct 20, 2025

@jmarrec
Copy link
Collaborator

jmarrec commented Oct 20, 2025

I'm happy enough with this to drop it into develop as this will make our lifes easier wiht the others PRs

@jmarrec jmarrec merged commit e68bea3 into develop Oct 20, 2025
1 of 6 checks passed
@jmarrec jmarrec deleted the v25.2.0-IOFreeze branch October 20, 2025 12:08
Comment on lines -45552 to -45555
\reference HeatPumpAirToWaterFuelFiredHeatingNames
\note Name of the fuel fired absorption heat pump system system
\reference-class-name validPlantEquipmentTypes
\reference validPlantEquipmentNames
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

That deletion was wrong. Causes OS-resources "heatpump_airtowater_fuelfired" to fail now

Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Fixed in bde9b4f

Comment on lines -45733 to -45734
\reference-class-name validPlantEquipmentTypes
\reference validPlantEquipmentNames
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Same here

jmarrec added a commit that referenced this pull request Oct 22, 2025
anchapin pushed a commit that referenced this pull request Nov 30, 2025
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

IDDChange Pull Request - Ready for CI This pull request if finalized and is ready for continuous integration verification prior to merge.

Projects

None yet

Development

Successfully merging this pull request may close these issues.

Update to EnergyPlus 25.2.0