Description

-Account for horizontal projection of tilted arrays in land lease calculations.
-Calculate land area per subarray, sum to total land area
-Use default assumptions when shading parameters are not enabled, use shading layout when shading is enabled
-Use default assumptions always for PVWatts
-Needs documentation

Fixes #826

Type of change

Please delete options that are not relevant.

  • Bug fix (non-breaking change which fixes an issue)
  • New feature (non-breaking change which adds functionality)
  • This change requires a documentation update

Checklist:

If you have added a new compute module in a SSC pull request related to this one, be sure to check the Process Requirements.

  • My code follows the style guidelines of this project
  • I have performed a self-review of my own code
  • I have commented my code, particularly in hard-to-understand areas
  • I have made corresponding changes to the documentation
  • My changes generate no new warnings
  • I have added tests that prove my fix is effective or that my feature works
  • New and existing unit tests pass locally with my changes
  • Any dependent changes have been merged and published in downstream modules
  • I have checked my code and corrected any misspellings

@mjprilliman mjprilliman added this to the 2021.12.02 Patch 1 milestone Feb 9, 2022
@mjprilliman mjprilliman self-assigned this Feb 9, 2022
@cpaulgilman cpaulgilman added the requires help revision Requires a Help revision before releasing public version label Feb 10, 2022
Copy link
Collaborator

@cpaulgilman cpaulgilman left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This looks great!

A couple of comments:

For Detailed PV, the land area calculations use tilt for 2-axis and seasonal tilt option. For 2-axis, I think tilt = 0 would be appropriate assuming trackers rest in horizontal position, and for seasonal, the minimum tilt angle would be appropriate. (Two-axis trackers are not usually arranged in rows, so I'm not sure how useful the land estimate is for that option, but I think we can leave that for now.)

For PVWatts, the calcs use GCR even when it is disabled for 2-axis tracking. Perhaps GCR should be enabled for all tracking options with UI text for 2-axis tracking: "For 2-axis tracking, the ground coverage ratio is only used for land area calculations."

calculations; added gcr warning for PVWatts 2-axis tracking (still used
for land area calcs)
Copy link
Collaborator

@cpaulgilman cpaulgilman left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Seasonal tilt option does not work: Should be if ( ${subarray1_track_mode} == 4), etc., not 3.

@mjprilliman mjprilliman merged commit 822d8bd into patch Feb 11, 2022
@mjprilliman mjprilliman deleted the land_area_calcs branch February 11, 2022 18:25
@cpaulgilman cpaulgilman removed the requires help revision Requires a Help revision before releasing public version label Feb 16, 2022
cpaulgilman added a commit that referenced this pull request Feb 17, 2022
Revise description of load data time convention.

Remove O&M cost content from Installation Costs topics.

Add ETES topics and fix broken help links.

Fix typo on battery storage FOM "BTM" insteasd of "FOM"

Wind resource files can now be .csv in addition to .srw

Revise capacity factor descriptions for PV and Battery storage configs, #905

Wave resource instructions for converting from time series to JPD, #892

Revise PV land area calculations to account for GCR and tilt angle, #928

Add pvlib column headings to SAM CSV format description, NREL/ssc#754

Revised Operating Cost input pages

Check for "annual energy" vs new "electricity to grid".

Change "battery autonomy" to "autonomy".

Revise power tower heliostat field to better explain how check box vs button works.

Add note for degradation by year that Year 1 value should be zero, #755

Remove debt from payback period description. Also remove detailed cash flow descriptions and replace with mention of send-to-Excel with equations and spreadsheets on website. See Amir Nashed email 1/19/21 and https://sam.nrel.gov/forum/forum-general/1052

Revise Electricity Purchases page to be specific for FOM projects

New LCOS metrics: #529

Electricity rates revisions from Brian.

Reporting of electricity bill in time series results, see NREL/ssc#652

New parametrics features

Parametrics description of how to work with SchedNumeric variables like PPA price. See Brian email 7/21/2021

Update Heliostat Field per #717

New PV slope inputs on System Design page. See #742, NREL/ssc#648

New "Limit debt fraction" Input on Financial Parameters page for PPA models

New ETES model.

Fix outdated description of NSRDB in Location and Resource topic

UDPC updates from Ty, see Revisions 2021 folder. Also post new PDF version of Ty and Matt's description under "CSP Power Cycle Models"  on SAM website https://sam.nrel.gov/concentrating-solar-power/csp-publications.html,  https://sam.nrel.gov/images/web_page_files/Neises-DRAFT-user-defined-power-cycle-v3-2018.pdf

Fix excess generation descriptions in help: https://sam.nrel.gov/forum/forum-general/3485. Also maybe change "Excess generation" to "Excess generation for net metering" or similar.

Note for URDB download that demand ratchet data in URDB is unreliable, so check with data sheet.

Demand charges with ratcheting lookback months. See Revision Notes mirletz-RE Adding billing demand lookback to SAM.msg, see [[F:\OneDrive\SAM\Utility Rates\Demand Ratchets\Initial Tests May 2021]]

Update pv smoothing per Steve's email 12/9/2021 "pv smoothing question"

Improve description of FOM automated dispatch. See https://sam.nrel.gov/forum/forum-general/3681

Revise electricity rates page

Consolidate weekday/weekend schedule descriptions.

SWH remove old hot water draw import instructions.

Revise electricity purchases PPA price option not available with Specify IRR target, and purchases treated as tax-deductible operating expense.

Move electricity purchases page to from Battery section to Electricity Rates and Load section

Edit Lifetime Data add note about pasting data from Excel: Thousands comma separator causes paste not to work correctly, e.g, 1,000 is pasted as 1.
@cpaulgilman cpaulgilman added the added to release notes PR and/or issue has been added to release notes for a public release label Feb 21, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

added to release notes PR and/or issue has been added to release notes for a public release enhancement

Projects

None yet

Development

Successfully merging this pull request may close these issues.

PV land area estimate should account for tilt angle and GCR

3 participants