The MMM-FroniusSolar5 module is an advanced evolution of the MMM-FroniusSolar family, specifically designed for MagicMirror² to monitor and visualize solar energy data from multiple Fronius inverters simultaneously. Building upon the animated flow visualization of MMM-FroniusSolar2, this version adds comprehensive support for systems with multiple inverters while maintaining all the dynamic visualization features.
1. Multi-Inverter Support
- Monitor multiple Fronius inverters simultaneously
- Aggregate data across all inverters for a complete system view
- Option to display individual inverter data side-by-side
2. Enhanced Data Processing
- Smart aggregation of power values (sum of all inverters)
- Intelligent SOC (State of Charge) averaging for battery systems
3. Improved Configuration
InverterIPsarray replaces singleInverterIP- New
ShowIndividualInverterstoggle for display modes
- Multi-Inverter Visualization:
- Combined view showing total system performance
- Optional individual inverter displays with IP identification
- Automatic data aggregation for P_Akku, P_Grid, P_Load, and P_PV
- Dynamic Gauges (retained from v2):
- Real-time animated SVG gauges for all power flows
- Color-coded based on energy direction (consumption vs production)
- Configurable maximum power values for proper scaling
- Animated Flow Lines:
- Dashed-line animations showing energy pathways
- Automatic direction changes based on power flow
- Color-coded by energy source/destination
- Smart Messaging System:
- Context-aware text messages based on grid interaction
- Fully customizable message thresholds and content
- Color-coded urgency levels
These are live pictures. The sum of the second picture doesn't match with the first of course. :-)
ShowIndividualInverters: false,
- Combined view showing total system performance
ShowIndividualInverters: true,
- Individual inverter display mode
- I use the Wlan IP and Network IP of the same inverter for the picture (I only have 1 inverter). This explains why the values are identical.
- Clone the repository into your MagicMirror/modules directory:
cd ~/MagicMirror/modules
git clone https://github.com/ChrisF1976/MMM-FroniusSolar5.git- Install dependencies:
cd MMM-FroniusSolar5
npm install cd ~/MagicMirror/modules/MMM-FroniusSolar5
git pull
npm installAdd the module to the config.js file:
{
module: "MMM-FroniusSolar5",
position: "bottom_center",
header: "Solar Monitoring",
config: {
InverterIPs: ["192.168.178.134", "192.168.178.84"], // Array of inverter IPs
updateInterval: 5*1000,
width: "300px",
icons: {
P_Akku: "mdi:car-battery",
P_Grid: "mdi:transmission-tower",
P_Load: "mdi:home-lightbulb",
P_PV: "mdi:solar-panel-large"
},
Radius: 50,
MaxPower: 4000,
MaxPowerPV: 10400,
ShowText: true,
ShowIndividualInverters: false, // Set to true to show each inverter separately
TextMessge: [
{ about: "600", Text: "Leicht erhöhter Netzbezug.", color: "#999" },
{ about: "1000", Text: "Na Na Na. Über 1 KW Netzbezug!", color: "#ffffff" },
{ about: "1500", Text: "Zu Wenig Sonne. Über 1,5KW Netzbezug. Warten?", color: "#eea205" },
{ about: "2500", Text: "Muss das wirklich sein? Über 2,5KW aus dem Netz!", color: "#ec7c25"},
{ about: "5000", Text: "Auto lädt, richtig? Nächstes Mal auf Sonne warten.", color: "#cc0605"},
{ less: "-500", Text: "Sonne scheint! Mehr als 500W frei.", color: "#f8f32b" },
{ less: "-2000", Text: "Wäsche waschen! Über 2KW freie Energie!", color: "#00bb2d"},
{ less: "-4000", Text: "Auto laden! Über 4KW freie Energie!", color: "f80000"},
],
},
},| Option | Default | Description |
|---|---|---|
InverterIPs |
[] |
Array of inverter IP addresses. |
ShowIndividualInverters |
false |
When true, shows each inverter's data separately |
updateInterval |
5*1000 (5 sec) |
Time interval (in milliseconds) between data updates from the Fronius system. |
icons |
N/A | Define custom Icons for power flow elements - Iconify |
Radius |
120 |
Radius of the SVG gauges (in pixels). |
MaxPower |
4000 |
Maximum power value for scaling P_Grid and P_Load gauges. |
MaxPowerPV |
10400 |
Maximum power value for scaling P_PV (solar panel power). |
ShowText |
true |
Enable or disable dynamic text messages below the gauges. |
TextMessge |
[] |
Array of objects defining conditional text messages based on P_Grid values. |
| Key | Description |
|---|---|
about |
Display the message when P_Grid exceeds this value. |
less |
Display the message when P_Grid is below this value. |
Text |
The message to display. |
color |
Color of the message text (hex or CSS color names). |
- Fetches real-time data from the Fronius system using the
node_helper.jsbackend.
- Gauges are created using SVG, displaying current values and percentages.
Power flows between elements (e.g., PV → Grid, PV → House) are represented as animated dashed lines.
- Displays context-sensitive messages based on
P_Gridvalues.
Custom styles can be adjusted in the MMM-FroniusSolar2.css file.
| Condition | Color | Description |
|---|---|---|
P_Akku - 100 > abs(P_Grid) |
#a3c49f |
Light green: High battery activity is contributing significantly to the house's energy consumption. |
P_Grid > 150 |
#808080 |
Gray: High grid consumption is being used to power the house. |
outerPower > 0 |
#00ff00 |
Green: Positive power flow (house is self-sufficient or partially consuming generated energy). |
outerPower < 0 |
#add8e6 |
Light blue: Energy is being exported to the grid (surplus power). |
- MagicMirror²
- Fronius Symo GEN24 with activated SolarApi.
All five modules, MMM-FroniusSolar, MMM-FroniusSolar2, MMM-FroniusSolar3, MMM-FroniusSolar4 and MMM-FroniusSolar5, are designed to display solar energy data. They share several configurations and CSS properties:
- Configuration Settings: Each module displays metrics such as
P_Akku,P_Grid,P_Load, andP_PVusing configurable icons and messages. - Dynamic SVG Gauges: All modules include gauges to represent power flow visually.
- Text Messages: Each module uses conditional text messages based on
P_Gridvalues.
- MMM-FroniusSolar: Best for simple setups prioritizing clarity and minimalism.
- MMM-FroniusSolar2: Suitable for scenarios requiring visual feedback on power flows (e.g., monitoring dynamic energy consumption).
- MMM-FroniusSolar3: Ideal for larger or customizable displays where scalability and enhanced readability are critical.
- MMM-FroniusSolar4: Similar to #2 but adds a Shelly support for monitoring small balcony solar systems.
- MMM-FroniusSolar5: Similar to #2 but monitors and visualize solar energy data from multiple Fronius inverters simultaneously
This module is distributed under the MIT License. See LICENSE for more details.