MMM-FroniusSolar4

Module #4 of the MMM-FroniusSolar-family (see below)

The MMM-FroniusSolar4 module is designed for the MagicMirror² platform to visualize solar energy data from a Fronius solar system and additional Shelly devices. It provides real-time visualization of energy flows and intuitive gauges for a comprehensive overview.

Features

  • Dynamic Gauges: Displays real-time data for:
    • P_Akku (Battery Power)
    • P_Grid (Grid Power)
    • P_Load (House Load)
    • P_PV (Solar Panel Power)
    • P_Shelly (Shelly PV Power)
  • Shelly Integration: Fetches and visualizes power data from Shelly devices (See MMM-ShellyPV for API instructions).
  • Text Messages: Provides contextual messages based on power grid usage.
  • Configurable Layout: Allows customization of radius, max power, and other gauge properties.

Screenshot

MMM-FroniusSolar4


Installation

  1. Clone the repository into your MagicMirror/modules directory:
   cd ~/MagicMirror/modules
   git clone https://github.com/ChrisF1976/MMM-FroniusSolar4.git
  1. Install dependencies:
cd MMM-FroniusSolar4
npm install

Configuration

Add the module to the config.js file:

{
    module: "MMM-FroniusSolar4",
    position: "bottom_right",
    header: "MMM-FroniusSolar4",
    config: {
        updateInterval: 5*1000, // Update Fronius Data every 5 seconds
        updateIntervalShelly: 30*1000, // Update Shelly Date every 30 seconds - keep a little higher to reduce API calls
        shellysPV: [
            { name: "PV Mini1", id: "xxxxxx" },
			{ name: "PV Mini2", id: "xxxxxx" },
			// Add more devices if necessary
		   ],
        icons: {
            P_Akku: "mdi:car-battery",
            P_Grid: "mdi:transmission-tower",
            P_Load: "mdi:home-lightbulb",
            P_PV: "mdi:solar-panel-large"
            P_Shelly: "mdi:solar-panel-large",
        },
        Radius: 120, // Radius for the SVG gauge
        MaxPower: 4000, // Maximum power for Grid scaling
        MaxPowerPV: 10400, // Maximum power for PV scaling
        MaxPowerShelly: 600, // Maximum power for shelly PV scaling
        ShowText: true,
        TextMessge: [
            { about: "600", Text: "Leicht erhöhter Netzbezug.", color: "#999" },
            { about: "1000", Text: "Über 1 KW Netzbezug!", color: "#ffffff" },
            { about: "1500", Text: "Über 1,5KW Netzbezug.", color: "#eea205" },
            { about: "2500", Text: "Über 2,5KW aus dem Netz!", color: "#ec7c25" },
            { about: "5000", Text: "Auto lädt, richtig? Nächstes Mal auf Sonne warten.", color: "#cc0605" },
            { less: "-500", Text: "Sonne scheint! Mehr als 500W frei.", color: "#f8f32b" },
            { less: "-2000", Text: "Wäsche waschen! Über 2KW freie Energie!", color: "#00bb2d" },
            { less: "-4000", Text: "Auto laden! Über 4KW freie Energie!", color: "#f80000" },
        ],
    },
},

Configuration Options

Option Default Description
InverterIP "192.168.178.134" IP address of the Fronius inverter to fetch solar energy data.
serverUriShelly "https://shelly-55-eu.shelly.cloud" URI for Shelly Cloud API to fetch additional PV system data. See MMM-ShellyPV for instructions
authKey "<your-shelly-auth-key>" Authentication key for accessing the Shelly API.
updateInterval 5*1000 (5 sec) Time interval (in milliseconds) between data updates from the Fronius system.
updateIntervalShelly 30*1000 (30 sec) Time interval (in milliseconds) between data updates from Shelly devices.
shellysPV [] Array of Shelly devices with name and id for monitoring additional PV systems.
icons N/A Define custom icons for power flow elements using Iconify.
Radius 80 Radius of the SVG gauges (in pixels).
MaxPower 1000 Maximum power value for scaling P_Grid and P_Load gauges.
MaxPowerPV 10400 Maximum power value for scaling P_PV (solar panel power).
MaxPowerShelly 600 Maximum power value for scaling P_Shelly (Shelly PV power).
ShowText true Enable or disable dynamic text messages below the gauges.
TextMessge [] Array of objects defining conditional text messages based on P_Grid values.

Text Message Format

Key Description
about Display the message when P_Grid exceeds this value.
less Display the message when P_Grid is below this value.
Text The message to display.
color Color of the message text (hex or CSS color names).

How It Works

Data Retrieval

  • Fetches real-time data from the Fronius system and Shelly API using the node_helper.js backend.

Visualization

  • Gauges are created using SVG, displaying current values and percentages.

Dynamic Messages

  • Displays context-sensitive messages based on P_Grid values.

Styling

Custom styles can be adjusted in the MMM-FroniusSolar4.css file.

House Gauge Color Logic

Condition Color Description
P_Akku - 100 > abs(P_Grid) #a3c49f Light green: High battery activity is contributing significantly to the house's energy consumption.
P_Grid > 150 #808080 Gray: High grid consumption is being used to power the house.
outerPower > 0 #00ff00 Green: Positive power flow (house is self-sufficient or partially consuming generated energy).
outerPower < 0 #add8e6 Light blue: Energy is being exported to the grid (surplus power).

Dependencies

  • MagicMirror²
  • Fronius Symo GEN24 with activated SolarApi.
  • Shelly device for PV power measuring

Common Features of MMM-FroniusSolar(X)

All 4 modules, MMM-FroniusSolar, MMM-FroniusSolar2, MMM-FroniusSolar3 and MMM-FroniusSolar4 are designed to display solar energy data. They share several configurations and CSS properties:

  • Configuration Settings: Each module displays metrics such as P_Akku, P_Grid, P_Load, and P_PV using configurable icons and messages.
  • Dynamic SVG Gauges: All modules include gauges to represent power flow visually.
  • Text Messages: Each module uses conditional text messages based on P_Grid values.

MMM-FroniusSolar4 All

Key Differences

  • MMM-FroniusSolar: Best for simple setups prioritizing clarity and minimalism.
  • MMM-FroniusSolar2: Suitable for scenarios requiring visual feedback on power flows (e.g., monitoring dynamic energy consumption).
  • MMM-FroniusSolar3: Ideal for larger or customizable displays where scalability and enhanced readability are critical.
  • MMM-FroniusSolar4: Similar to #2 but adds a Shelly support for monitoring small balcony solar systems.
  • MMM-FroniusSolar5: Similar to #2 but monitors and visualize solar energy data from multiple Fronius inverters simultaneously

License

This module is distributed under the MIT License. See LICENSE for more details.

About

visualize solar energy data from a Fronius solar system and additional Shelly devices

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

 
 
 

Contributors