Skip to main content
Suchen Sie etwas anderes?
In this section it is possible to send an AT command directly to the router’s internal modem. For example, it could be interesting to check the network coverage, identify the telephone cells in the area, etc.
It is also possible to configure up to five special AT commands which can be used to configure the router upon startup.
- AT Command: AT command for real time execution (for example AT+CSQ). Once “SEND AT COMMAND” is clicked, the command will be executed
- AT1… AT5: start up AT commands

ADDITIONAL NOTES
- Once the configuration is finished, click “SAVE CONFIG” to save the changes. Remember that the router should be restarted for the changes to take effect.

Enter the “ethernet” or “modem” connection type:
For an ethernet configuration, make sure the IP parameters are compatible with server access according to the concentrator local network configuration. For an ethernet connection, the configuration must be compatible with the concentrator’s local network topology so that it can access the servers. This configuration is done from the “Networks” configuration page (see section 3.2.2.3: “Networks”).
For a modem connection, the modem configuration must be correct before a connection can be set up. This configuration is done from the “Modem” configuration page (see section 3.2.2.4: “Modem”).
The parameters for the servers to be configured are at least the following:
Therefore the following fields need to be configured: “Interface”, “Type”, “Server type”, “Address”, “Port”, “Login” and “Password”.
The other fields can be left at the default values subject to the directories having been properly created beforehand. See section 3.1.2: “Configuration files” for more details.

Wait. The concentrator will reboot using its factory configuration.