MMU configuration for DellEMC Z9332 systems in T0 and T1 topolgy#7973
Merged
yxieca merged 1 commit intosonic-net:masterfrom Jun 26, 2021
vmittal-msft:z9332_mmu
Merged
MMU configuration for DellEMC Z9332 systems in T0 and T1 topolgy#7973yxieca merged 1 commit intosonic-net:masterfrom vmittal-msft:z9332_mmu
yxieca merged 1 commit intosonic-net:masterfrom
vmittal-msft:z9332_mmu
Conversation
gechiang
reviewed
Jun 25, 2021
|
|
||
| {%- set default_cable = '300m' %} | ||
|
|
||
| {%- macro generate_port_lists(PORT_ALL) %} |
Collaborator
There was a problem hiding this comment.
I see how this mapping goes with the 100G and 400G ports defined for this HW SKU. But there are 2 10G ports as well but I don't see that included here... is it being handled differently?
prsunny
approved these changes
Jun 25, 2021
yxieca
pushed a commit
that referenced
this pull request
Jun 26, 2021
Why I did it MMU configuration for DellEMC Z9332 systems in T0/T1 topology How I did it Updated config.bcm, QoS/Buffer pool and lossy/lossless profile settings How to verify it Verified that Dell systems are booting up fine and basic test cases passing.
This was referenced Jul 1, 2021
carl-nokia
pushed a commit
to carl-nokia/sonic-buildimage
that referenced
this pull request
Aug 7, 2021
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Why I did it
MMU configuration for DellEMC Z9332 systems in T0/T1 topology
How I did it
Updated config.bcm, QoS/Buffer pool and lossy/lossless profile settings
How to verify it
Verified that Dell systems are booting up fine and basic test cases passing.
Which release branch to backport (provide reason below if selected)
202012-internal
Description for the changelog
MMU configuration for DellEMC Z9332 systems in T0/T1 topology
A picture of a cute animal (not mandatory but encouraged)