fix Serial.flush() blocks forever #597#652
Merged
facchinm merged 1 commit intoarduino:masterfrom Oct 20, 2021
Merged
Conversation
* The aynchronous nature of the DRE and TXC interrupt flags causes issues (lockups) when the TX DATA register is empty on start and a flush is issued. Simply looking at the DRE prior to waiting for TXC is insufficient because the data register may well be empty but the shift register could still contain data, in this case SERCOM::flushUART() would return before TXC has been raised thus before flushing is complete. * bool added to SERCOM.h to indicate when it is ok for SERCOM::flushUART() to wait for the TXC flag. This flag is set when any data is written to the data register via SERCOM::writeDataUART(). It is cleared when a flush is done.
|
✅ Build completed. ⬇️ Build URL: ℹ️ To test this build:
|
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
causes issues (lockups) when the TX DATA register is empty on start
and a flush is issued. Simply looking at the DRE prior to
waiting for TXC is insufficient because the data register
may well be empty but the shift register could still contain
data, in this case SERCOM::flushUART() would return before TXC
has been raised thus before flushing is complete.
SERCOM::flushUART() to wait for the TXC flag. This flag is
set when any data is written to the data register via
SERCOM::writeDataUART(). It is cleared when a flush is done.
Fixes #597