Description
Issue overview
E+ 25.2 is creating a warning about an unused object (Coil:WaterHeating:AirToWaterHeatPump:Wrapped). The object is definitely used and did not produce a warning in E+ 25.1.
** Warning ** The following lines are "Unused Objects". These objects are in the input
** ~~~ ** file but are never obtained by the simulation and therefore are NOT used.
** ~~~ ** Only the first unused named object of an object class is shown. Use Output:Diagnostics,DisplayAllWarnings; to see all.
** ~~~ ** See InputOutputReference document for more details.
************* Object=Coil:WaterHeating:AirToWaterHeatPump:Wrapped=water heater coil
This change is most likely due to #11033.
Operating System (Multiple choices)
Ubuntu
Operating System Version
24.04
Version of EnergyPlus
25.2.0 RC1
Unmethours link or helpdesk ticket number
N/A
Defect file