Units incorrect in IDD for tank loss coefficient (UA) for WATERHEATER:SIMPLE (CR #5850) #800

@axelstudios

Description

@axelstudios
Added on 2003-06-23 13:02 by @mjwitte

Description

MJW 23Jun2003
User pointed out that units for tank loss coefficient (UA) for WATERHEATER:SIMPLE should be [W/K], not [J/K]. Comments in source code are correct, indicating [W/K]

Also need to add units to documentation for all fields for this object.

MJW 22Aug2003
Revised docs sent to LKL.

External Ref: USR #1440, waspoorboy mingsbox@edirect168.com, 20Jun2003
Addressed in 03.08.22 V1.1.1.007 by @lklawrie
Last build tested: 03.08.22 V1.1.1.007