Compact HVAC - Reactivate optional bypass logic after plant iteration issues are resolved
Added on 2005-04-12 13:26 by @mjwitte
Description
MJW 12 Apr 2005
Boiler and chiller min plrs were set to zero to eliminate max iteration issues. When CR6647 has been addressed, it should be safe to use supply side bypass only as needed (bypass with constant flow configuration only). Bypasses were added for all cases before the issues involved were well known, so it might be safe to implement this now, but it is too late in the game to do for this release.
MJW 16 Oct 2007
Given the status of CR7352 "Incorrect occurence of fatal error "Branches cannot handle all the flow"", it is best to keep BYPASS pipes in place on both sides of plant loops for the time being.
MJW 02 Jan 2008
Added to enhancement list, doc file is HVAC_2008_01.doc
Further Details for Users
HVAC_2008_01
Addressed in 08.01.07 V2.2.0.004 by @mjwitte
Last build tested: 05.04.10 V1.2.2.027