Testomat Automatic Hardness Control

Automatic hardness control
The Testomat automatic determines the residual/total hardness via titration. Ideal for the water quality after water softeners, water blender and drinking-water plants.
The Testomat EVO TH is the successor to the Testomat ECO.
- Automatic sampling
- Reliable, accurate measurement results
- Easy to operate
- Automatic venting
- Measures total or residual hardness
- Available version with a calibration function
- Optical water detection
- Open drain
- SD card
- Self-test
- RS232 port
- External alarm clearing

The Testomat Family
Automatically determines the residual or total water hardness, the carbonate hardness, the p-value or the minus-m-value via titration. The 2000 can measure two individual measuring points.
This analysis instrument enables the measurement of two different parameters simultaneous, e.g. two different measuring ranges for water hardness.
This Testomat correspond in function and suitability to the Testomat 2000, but has an additional calibration function in order to balance possible interference.
This Testomat is "the good value alternative" for the Testomat 2000, it determines through titration the water hardness from a single measurement point. The Testomat Eco or Testomat 2000 replace the Testomat F-bob
This Testomat version, in combination with a 3/2-way-motor operating valve is an easy to use control system for water blending plant
The process-photometer Testomat 2000 CLT is a wet-chemical online instrument for monitoring the content of total chlorine in the 0–2.5 mg/l (ppm) range and it can be switched to free chlorine.
• Analysis via automatic dosing of 3 reagents; the analysis result is displayed after a reaction time of approx. two minutes
• Application areas: Monitoring of chlorination plants for drinking water or swimming pools– Provides protection for reverse osmosis membranes.
The process-photometer Testomat 2000 CLF is a wet-chemical online instrument for monitoring the content of free chlorine in the0–2.5 mg/l (ppm) range.
The process photometer Testomat 2000 THCL determines the content of total chlorine in the 0 to 2.5 mg/l (ppm) range using the colorimetric analysis principle and the existing water hardness via titration.
The process photometer Testomat 2000 Fe is a wet-chemical online monitor for monitoring the content of dissolved iron (II) + (III) in the 0 to 1.0 mg/l (ppm) range using the colorimetric method.
• Dosing of 2 reagents and display of the analysis value after a reaction time of approx. 7 minutes (absolute measuring time without flushing times)
Model | Measure range° dH | Ambient temperature°C | Operating pressurebar | inlet ODmm | outlet ODmm | B x H x Tmm | WeightKg | Application | |
| Silica SiO2 0.3 - 1.2 | 10 - 40 | 0.3 - 1 | 6 | 6 | 364 x 314 x 138 | 4,35 | Sterilisation of hospitals Measuring silica | ![]() | |
| 0.02 - 3 | 10 - 40 | 0.3 - 1 1 - 4 | 6 | 6 | 364 x 314 x 138 | 4,35 | reverse osmosis pure water galvanization | ![]() | |
| 0.05 - 25 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9 | water treatment drinking water | ![]() | |
| 0.5 - 10.0 carbonate hardness 1.0 - 20.0 acid capacity | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9 | water treatment swimming pools | ![]() | |
| 0.05 - 25 | 10 - 40 | 0.3 - 1 1 - 8 | 6 | 12 ID | 380 x 480 x 280 | 9 | water treatment monitoring proceswater drinking water | ![]() | |
| 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | water treatment drinking water watersoftening decarbonization desalination boiler houses cooling towers | ![]() | |
| 0.05 - 25 water harness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | water treatment drinking water watersoftening decarbonization desalination boiler houses cooling towers | ![]() | |
| 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | control water quality pharmaceutical industry | ![]() | |
| 1.0 - 25 water hardness 1.0 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | water blending process water | ||
| 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | difficult water, calcium, biofilms extending life reducing contamination | ||
| 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | control of water quality can arise due to oxidizing agents | ||
| 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | use two circuits for diferent hardness measurment inlet - outlet | ||
| Testomat 2000 DUO CN | 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | use two circuits for diferent hardness measurment inlet - outlet | |
| free chlorine 0.0 - 0.99 / 1.0 - 2.5 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring chlorination drinking water swimming pool water | ||
| free chlorine 0.0 - 0.99 / 1.0 - 2.5 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring chlorination drinking water swimming pool water protection RO membranes | ||
| free chlorine 0.0 - 0.99 / 1.0 - 2.5 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring desinfection drinking water process water | ||
| 0 - 1.88 / 1.0 - 4.7 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring desinfection drinking water process water | ||
| free chlorine 0.0 - 0.99 mg/l / 0.25 - 2.50 water hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | dialysis corrosion protection protection RO membranes monitoring drinking water /swimming pools | ||
| 0 - 2.23 / 2.3 - 5.6 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring dosing disinfectants | ||
| chromate 0.0 - 0.99 / 1.0 - 2.0 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring chromate control of waste water | ||
| 0.0 - 0.65 / 0.7 - 1.0 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitorig removing iron control drinking water | ||
| 0.0 - 50.0 mg/l | 10 - 45 | 0.3 - 1 1 - 4 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring conditioning cooling and heating | ||
| 0.0 - 10.0 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | process water water purification waste water treatment | ||
| sulfite 0.0 - 9.9 / 10 - 20 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring sulfite for oxygen binding boiler water | ||
| 5 - 150 °KH 2 - 60 °KH | 10 - 45 | 0.3 - 1 1 - 4 | 6 | 6 | 380 x 480 x 280 | 9,5 | alkalinity of coolant circuits | ![]() | |
| 0.05 - 1.0 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring corrosion boiler water decarbonization | ![]() | |
| 0.05 - 2.0 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring corrosion boiler water decarbonization | ||
| 2.5 - 50.0 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | drinking water raw water | ||
For a direct quotation or a Testamat price list, please contact us:
Feedback Form or call us on +31 152 610 900
Lenntech (European Head Office)
Distributieweg 3
2645 EG Delfgauw
The Netherlands
Phone: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com
Lenntech USA LLC (Americas)
5975 Sunset Drive
South Miami, FL 33143
USA
Phone: +1 877 453 8095
e-mail: info@lenntech.com
Lenntech DMCC (Middle East)
Level 6 - OFFICE #101-One JLT Tower
Jumeirah Lake Towers
Dubai - U.A.E.
Phone: +971 4 429 5853
e-mail: info@lenntech.com
Copyright © 1998-2026 Lenntech B.V. All rights reserved