Lenntech Water treatment & purification Lenntech Water treatment & purification

Testomat Automatic Hardness Control

  

Automatic hardness control

The Testomat automatic determines the residual/total hardness via titration. Ideal for the water quality after water softeners, water blender and drinking-water plants.

The Testomat EVO TH is the successor to the Testomat ECO.

  • Automatic sampling
  • Reliable, accurate measurement results
  • Easy to operate
  • Automatic venting
  • Measures total or residual hardness
  • Available version with a calibration function


  • Optical water detection
  • Open drain
  • SD card
  • Self-test
  • RS232 port
  • External alarm clearing

The Testomat Family

Automatically determines the residual or total water hardness, the carbonate hardness, the p-value or the minus-m-value via titration. The 2000 can measure two individual measuring points.

This analysis instrument enables the measurement of two different parameters simultaneous, e.g. two different measuring ranges for water hardness.

This Testomat correspond in function and suitability to the Testomat 2000, but has an additional calibration function in order to balance possible interference.

This Testomat is "the good value alternative" for the Testomat 2000, it determines through titration the water hardness from a single measurement point. The Testomat Eco or Testomat 2000 replace the Testomat F-bob

This Testomat version, in combination with a 3/2-way-motor operating valve is an easy to use control system for water blending plant

The process-photometer Testomat 2000 CLT is a wet-chemical online instrument for monitoring the content of total chlorine in the 0–2.5 mg/l (ppm) range and it can be switched to free chlorine.
• Analysis via automatic dosing of 3 reagents; the analysis result is displayed after a reaction time of approx. two minutes
• Application areas: Monitoring of chlorination plants for drinking water or swimming pools– Provides protection for reverse osmosis membranes.

The process-photometer Testomat 2000 CLF is a wet-chemical online instrument for monitoring the content of free chlorine in the0–2.5 mg/l (ppm) range.

The process photometer Testomat 2000 THCL determines the content of total chlorine in the 0 to 2.5 mg/l (ppm) range using the colorimetric analysis principle and the existing water hardness via titration.

The process photometer Testomat 2000 Fe is a wet-chemical online monitor for monitoring the content of dissolved iron (II) + (III) in the 0 to 1.0 mg/l (ppm) range using the colorimetric method.
• Dosing of 2 reagents and display of the analysis value after a reaction time of approx. 7 minutes (absolute measuring time without flushing times)

Model
Measure range
° dH
Ambient temperature
°C
Operating pressure
bar
inlet OD
mm
outlet OD
mm
B x H x T
mm
Weight
Kg
Application

Testomat 808 SiO2

Silica SiO2

0.3 - 1.2

10 - 40 0.3 - 1 6 6 364 x 314 x 138 4,35

Sterilisation of hospitals

Measuring silica

Testomat 808

0.02 - 3 10 - 40

0.3 - 1

1 - 4

6 6 364 x 314 x 138 4,35

reverse osmosis
water softening

pure water

galvanization

Testomat ECO

0.05 - 25 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9 water treatment
drinking water

Testomat ECO C

0.5 - 10.0 carbonate hardness

1.0 - 20.0 acid capacity

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9

water treatment
drinking water

swimming pools

Testomat EVO TH

0.05 - 25 10 - 40

0.3 - 1

1 - 8

6 12 ID 380 x 480 x 280 9

water treatment
industrial boilers

monitoring proceswater

drinking water

Testomat 2000

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

water treatment
water blending

drinking water

watersoftening

decarbonization

desalination

boiler houses

cooling towers

Testomat 2000 CN

0.05 - 25 water harness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

water treatment
water blending

drinking water

watersoftening

decarbonization

desalination

boiler houses

cooling towers

Testomat 2000 CAL

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

control water quality

pharmaceutical industry

Testomat 2000 V

1.0 - 25 water hardness

1.0 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

water blending

process water

Testomat 2000 self clean

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

difficult water, calcium, biofilms

extending life

reducing contamination

Testomat 2000 Antox

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

control of water quality

can arise due to oxidizing agents

Testomat 2000 DUO

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

use two circuits for diferent hardness

measurment inlet - outlet

Testomat 2000 DUO CN

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

use two circuits for diferent hardness

measurment inlet - outlet

Testomat 2000 CLF

free chlorine 0.0 - 0.99  / 1.0 - 2.5 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring chlorination

drinking water

swimming pool water

Testomat 2000 CLT

free chlorine 0.0 - 0.99  / 1.0 - 2.5 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring chlorination

drinking water

swimming pool water

protection RO membranes

Testomat 2000 CLT self clean

free chlorine 0.0 - 0.99  / 1.0 - 2.5 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring desinfection

drinking water

process water

Testomat 2000 CLO2

0 - 1.88 / 1.0 - 4.7 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring desinfection

drinking water

process water

Testomat 2000 THCL

free chlorine 0.0 - 0.99 mg/l /

0.25 - 2.50 water hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

dialysis

corrosion protection

protection RO membranes

monitoring drinking water /swimming pools

Testomat 2000 Br

0 - 2.23 / 2.3 - 5.6 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5 monitoring dosing disinfectants

Testomat 2000 CrVl

chromate 0.0 - 0.99 / 1.0 - 2.0 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring chromate

control of waste water

Testomat 2000 Fe

0.0 - 0.65 / 0.7 - 1.0 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitorig removing iron

control drinking water

Testomat 2000 Polymer

0.0 - 50.0 mg/l 10 - 45

0.3 - 1

1 - 4

6 6 380 x 480 x 280 9,5 monitoring conditioning cooling and heating

Testomat 2000 PO4

0.0 - 10.0 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

process water

water purification

waste water treatment

Testomat 2000 SO3

sulfite 0.0 - 9.9 / 10 - 20 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring sulfite for oxygen binding

boiler water

Titromat KH

5 - 150 °KH

2 - 60 °KH

10 - 45

0.3 - 1

1 - 4

6 6 380 x 480 x 280 9,5 alkalinity of coolant circuits

Titromat M1

0.05 - 1.0 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring corrosion boiler water

decarbonization

Titromat M2

0.05 - 2.0 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring corrosion boiler water

decarbonization

Titromat TH

2.5 - 50.0 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

drinking water

raw water

For a direct quotation or a Testamat price list, please contact us: Feedback Form or call us on +31 152 610 900

Lenntech (European Head Office)

Distributieweg 3
2645 EG Delfgauw
The Netherlands
Phone: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com


Lenntech USA LLC (Americas)

5975 Sunset Drive
South Miami, FL 33143
USA
Phone: +1 877 453 8095
e-mail: info@lenntech.com


Lenntech DMCC (Middle East)

Level 6 - OFFICE #101-One JLT Tower
Jumeirah Lake Towers
Dubai - U.A.E.
Phone: +971 4 429 5853
e-mail: info@lenntech.com



Lenntech terms of business are according to Orgalime SI 24 conditions. A copy can be provided on request.

Copyright © 1998-2026 Lenntech B.V. All rights reserved