From Guesswork to Gold Standard:
Precision Fluid Measurement
Move beyond the limitations of proxy markers and physical exams. Blood Volume Analysis (BVA™) delivers definitive, actionable data to optimize volume management across the entire care continuum.

Achieve better outcomes with BVA, delivering excellent healthcare value
with reimbursement.
Published Research from Leading
Institutions Has Established the Value
of Blood Volume Measurement Using BVA
![]()
![]()
![]()
![]()
![]()
![]()
Precision in Critical Care
& Chronic Disease
Why is accurate fluid assessment measurement critical in Sepsis, ARDS, and Heart Failure? Inaccurate fluid assessment is a significant risk factor in complex, life-threatening conditions. BVA provides the diagnostic clarity needed to navigate the challenges of both acute and chronic conditions.
Examples

Heart Failure

Critical Care

Sepsis

Syncope

Surgical Blood Loss

ARDS
Daxor’s BVA offers clinicians a precise tool to optimize fluid management,
reduce healthcare costs, and improve outcomes in these high-impact areas.
From Data to Decision in 3 Steps
We’ve simplified the path to clinical certainty. BVA integrates seamlessly into existing workflows to provide actionable data when it matters most.
-
1
Quantify
BVA captures a precise snapshot of the patient’s unique blood volume physiology through simple blood draws using the indicator dilution technique.
-
2
Analyze
BVA automatically quantifies total blood, plasma, and red cell volumes with >95% accuracy, revealing the hidden fluid imbalances that indirect measures miss.
-
3
Optimize
Clinicians receive an objective, actionable diagnostic report to immediately adjust fluids or medications—moving from trial and error to data-driven precision medicine.
Understanding More for
Providers, Payers, Patients
Newsroom
From peer-reviewed data to hospital success stories, see how
BVA is redefining the standard of care in fluid management.

BVA Made Easy
Simplify volume management with our
intuitive BVA calculator, guidance, insightful case studies, and protocols effortlessly.
- Get accurate BVA result findings instantly
- Case studies and Learning at your fingertips
- Get fast Clinical Support from Daxor
Download today to unlock the
power of precision with the new
BVA Mobile Companion App.
Important Safety Information
The information provided on this website is for general informational purposes only and is not a substitute for professional medical advice, diagnosis, or treatment. Always seek the advice of your physician or other qualified health provider with any questions you may have regarding a medical condition.
The data provided by the BVA is to assist qualified healthcare professionals in patient diagnosis and management. The uses and benefits of the BVA test described on this website are based on scientific literature and clinical experience. However, individual patient outcomes may vary. This website is not intended to promote any off-label uses of the BVA device. Decisions regarding the use of the BVA test and the interpretation of its results must be made by a qualified healthcare professional. Daxor is not responsible for any actions or decisions taken based on the information provided on this website.
BVA™ and Volumex® Indication and Important Risk Information
Indications and Intended Use
The Daxor BVA is an automated system that is used to measure/calculate the red cell mass (mL), plasma volume (mL) and total blood volume (mL), along with the related deviations from ideal values by amount (mL) and percentage (%) in adults. In addition, the Normalized Hematocrit (%) and Albumin Transudation Rate (%/min) are calculated.
It is an in vitro medical device composed of a microprocessor, software, touchscreen, and gamma counter and accessory convenience kit. The Daxor BVA is intended to calculate human blood volumes by the method of tracer diffusion (Indicator dilution technique) with I-131 as the tracer after injection of I-131 Human Serum Albumin.
The Daxor BVA provides a Quantitative Assessment of total blood and plasma volumes using an automated system.
Data inputs to the software come from the measured characteristics of patient venous whole blood samples collected in K3EDTA vacutainer tubes (hematocrit and tracer concentration) and tracer calibration standards. The patient blood samples and the calibration standards are measured in a gamma counter, whose output is automatically input to this calculation program. The package also calculates the patient expected (or ideal) blood volume from physical parameters. Hyper- or hypovolemia, and associated red cell volumes are reported, with statistics showing the quality of the results.
For in vitro diagnostic use in a Clinical Laboratory setting and operated by laboratory technicians. Rx use only.
Contraindications and Clinical Postponement
Volumex is contraindicated for use in pregnant women. Furthermore, safety and effectiveness have not been established in pediatric or nursing patients. While there are otherwise no known contraindications for Volumex, the procedure should be deferred if the patient is unwilling to consent, if reliable venous access cannot be established, or if the patient is clinically unstable (e.g., experiencing chest pain or shortness of breath) unless under direct physician oversight.
Safety Precautions and Radiation Management
Minimize radiation exposure for patients and workers; radiopharmaceuticals must only be handled by qualified, licensed handlers. Lugol’s Solution may be administered starting 24 hours pre-injection to protect the thyroid. Keep the BVA at least 3 meters from interference sources like MRI or electrosurgical equipment.
Potential Adverse Events
Potential risks include theoretical allergic reactions and injection site infiltration; the total weekly dosage must not exceed 200 microcuries. Ensure accurate, current height and weight are used for “ideal” volume calculations.
Device and Material Caution
Visually inspect Volumex; discard if particulates are present or if coloration is darker than very pale yellow. Total weekly dosage must not exceed 200 microcuries. Accurate patient height and weight measurements are required to calculate “ideal” volumes; do not use patient history. Clean the unit enclosure with mild detergent or 10% bleach, but never use alcohol on the screen.
Disposal Procedures
Dispose of empty Volumex syringes in an appropriate sharps container after assaying. Blood samples and cartridges may be discarded as standard medical waste in a biohazard container.