{"id":1927,"date":"2018-09-14T07:57:44","date_gmt":"2018-09-14T14:57:44","guid":{"rendered":"https:\/\/testrium.com\/?p=1927"},"modified":"2020-08-19T11:21:04","modified_gmt":"2020-08-19T15:21:04","slug":"accelerometer-selection-for-vibration-testing","status":"publish","type":"post","link":"https:\/\/testrium.com\/accelerometer-selection-for-vibration-testing\/","title":{"rendered":"Accelerometer Selection for Vibration Testing"},"content":{"rendered":"<h1>Accelerometer Selection for Vibration Testing<\/h1>\n<p>When you boil it down to its essentials, <a href=\"https:\/\/testrium.com\/testing-services\/dynamic-testing\/vibration-testing-services\/\">vibration testing<\/a> is about introducing a specified level of energy into a DUT at or over a range of frequencies. We normally control and measure that energy with one or more <a href=\"https:\/\/en.wikipedia.org\/wiki\/Accelerometer\">accelerometers<\/a>. Understanding the capabilities of these accelerometers is important to ensure that vibration energy is introduced into the DUT within the specified limits.<\/p>\n<p>Some of the more significant accelerometer characteristics that you need to consider when selecting an accelerometer for a vibration test are sensitivity, frequency response, temperature and mass loading. An accelerometer\u2019s sensitivity is the ratio of its output (in mV or picocoulombs) to its input in g\u2019s. If you\u2019re performing a test at a low level (like 0.25g rms) it\u2019s necessary to select an accelerometer that has a high sensitivity otherwise the controller will not receive a signal higher than the background electrical noise and will be unable to control the <a href=\"https:\/\/testrium.com\/testing-services\/dynamic-testing\/vibration-testing-services\/bsr-testing\/\">shaker<\/a>.<\/p>\n<p>Accelerometers are designed to measure acceleration accurately over a range of frequencies. Some are optimized for lower frequencies, even down to DC levels, others are good at measuring at very high frequencies but can\u2019t accurately measure below 2 hz. Because of this, it\u2019s necessary to match the frequency response of the accelerometer to the frequency range of your test profile. The manufacturers\u2019 specification for the accelerometer will define the acceptable frequency range for the accelerometer.<\/p>\n<p>The temperature which an accelerometer is exposed to will affect its sensitivity and can significantly change the acceleration values that you\u2019re measuring. Again, the manufacturers\u2019 specification for the accelerometer should be consulted to ensure that your accelerometer will measure accurately at the temperature under which you\u2019re testing.<\/p>\n<p>The mass of the accelerometer that you attach to your DUT, will change the mass of the DUT itself. When you change the mass of your DUT, you also change its frequency response, so that the resonance that you measure with a 5 gram accelerometer will not be the same frequency if you\u2019ve mounted a lightweight 0.5 gram accelerometer to your circuit board.<\/p>\n<p>Choose your accelerometers carefully for the condition you want to measure and environment they will experience.<\/p>\n<p><iframe loading=\"lazy\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/T7NWmSkbR10\" width=\"100%\" height=\"415\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Accelerometer Selection for Vibration Testing When you boil it down to its essentials, vibration testing is about introducing a specified level of energy into a DUT at or over a range of frequencies. We normally control and measure that energy with one or more accelerometers. Understanding the capabilities of these accelerometers is important to ensure<a href=\"https:\/\/testrium.com\/accelerometer-selection-for-vibration-testing\/\">[&#8230;]<\/a><\/p>\n","protected":false},"author":2,"featured_media":1952,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[14,7,11],"tags":[],"class_list":["post-1927","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bsr-testing","category-testing","category-vibration-testing"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Accelerometer Selection for Vibration Testing - Paragon Systems Testing<\/title>\n<meta name=\"description\" content=\"When you boil it down to its essentials, vibration testing is about introducing a specified level of energy into a DUT at or over a range of frequencies.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/testrium.com\/accelerometer-selection-for-vibration-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Accelerometer Selection for Vibration Testing\" \/>\n<meta property=\"og:description\" content=\"When you boil it down to its essentials, vibration testing is about introducing a specified level of energy into a DUT at or over a range of frequencies.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/testrium.com\/accelerometer-selection-for-vibration-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Testrium Inc\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/testriumlab\" \/>\n<meta property=\"article:published_time\" content=\"2018-09-14T14:57:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-19T15:21:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/testrium.com\/wp-content\/uploads\/2018\/09\/accelerometer-selection.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"465\" \/>\n\t<meta property=\"og:image:height\" content=\"260\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"ParagonAdmin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@testriumlab\" \/>\n<meta name=\"twitter:site\" content=\"@testriumlab\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"ParagonAdmin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<meta property=\"og:video\" content=\"https:\/\/www.youtube.com\/embed\/T7NWmSkbR10\" \/>\n<meta property=\"og:video:type\" content=\"text\/html\" \/>\n<meta property=\"og:video:duration\" content=\"264\" \/>\n<meta property=\"og:video:width\" content=\"480\" \/>\n<meta property=\"og:video:height\" content=\"270\" \/>\n<meta property=\"ya:ovs:adult\" content=\"false\" \/>\n<meta property=\"ya:ovs:upload_date\" content=\"2018-09-14T14:57:44+00:00\" \/>\n<meta property=\"ya:ovs:allow_embed\" content=\"true\" \/>\n<meta name=\"geo.placename\" content=\"Concord\" \/>\n<meta name=\"geo.position\" content=\"43.8216396;-79.4989484\" \/>\n<meta name=\"geo.region\" content=\"Canada\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Accelerometer Selection for Vibration Testing - Paragon Systems Testing","description":"When you boil it down to its essentials, vibration testing is about introducing a specified level of energy into a DUT at or over a range of frequencies.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/testrium.com\/accelerometer-selection-for-vibration-testing\/","og_locale":"en_US","og_type":"article","og_title":"Accelerometer Selection for Vibration Testing","og_description":"When you boil it down to its essentials, vibration testing is about introducing a specified level of energy into a DUT at or over a range of frequencies.","og_url":"https:\/\/testrium.com\/accelerometer-selection-for-vibration-testing\/","og_site_name":"Testrium Inc","article_publisher":"https:\/\/www.facebook.com\/testriumlab","article_published_time":"2018-09-14T14:57:44+00:00","article_modified_time":"2020-08-19T15:21:04+00:00","og_image":[{"width":465,"height":260,"url":"https:\/\/testrium.com\/wp-content\/uploads\/2018\/09\/accelerometer-selection.jpg","type":"image\/jpeg"}],"author":"ParagonAdmin","twitter_card":"summary_large_image","twitter_creator":"@testriumlab","twitter_site":"@testriumlab","twitter_misc":{"Written by":"ParagonAdmin","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":false},"og_video":"https:\/\/www.youtube.com\/embed\/T7NWmSkbR10","og_video_type":"text\/html","og_video_duration":"264","og_video_width":"480","og_video_height":"270","ya_ovs_adult":"false","ya_ovs_upload_date":"2018-09-14T14:57:44+00:00","ya_ovs_allow_embed":"true","geo.placename":"Concord","geo.position":{"lat":"43.8216396","long":"-79.4989484"},"geo.region":"Canada"},"_links":{"self":[{"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/posts\/1927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/comments?post=1927"}],"version-history":[{"count":0,"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/posts\/1927\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/media\/1952"}],"wp:attachment":[{"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/media?parent=1927"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/categories?post=1927"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/testrium.com\/wp-json\/wp\/v2\/tags?post=1927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}