{"id":2543,"date":"2017-05-02T13:39:13","date_gmt":"2017-05-02T17:39:13","guid":{"rendered":"https:\/\/support.mindwaretech.com\/?post_type=ht_kb&#038;p=2543"},"modified":"2017-05-02T13:39:13","modified_gmt":"2017-05-02T17:39:13","slug":"kb0067","status":"publish","type":"ht_kb","link":"https:\/\/support.mindwaretech.com\/knowledge-base\/kb0067\/","title":{"rendered":"KB0067: Scaling Skin Temperature to Degrees"},"content":{"rendered":"<p>The typical <a href=\"http:\/\/www.mindwaretech.com\/product_detail.asp?ItemID=1553\">skin temperature probe<\/a> used with MindWare systems requires a modified\u00a0<a href=\"http:\/\/www.mindwaretech.com\/product_detail.asp?ItemID=1518\">Transducer BioNex module<\/a>\u00a0to use. \u00a0As with all transducers, the data will initially be displayed in volts. To scale this data to degrees (Fahrenheit or Celsius) \u00a0you need to apply a known scaling equation in either <a href=\"http:\/\/www.mindwaretech.com\/product_detail.asp?ItemID=1850\">BioLab<\/a> or the <a href=\"http:\/\/www.mindwaretech.com\/product_detail.asp?ItemID=2000\">Basic Signal Analysis (BSA) application<\/a>.<\/p>\n<hr \/>\n<h2><\/h2>\n<h2>Skin Temperature Scaling Equation<\/h2>\n<p>The following equation needs to be applied to skin temperature data to scale it to degrees Fahrenheit:<\/p>\n<p style=\"padding-left: 30px;\"><strong>deg F = [(50\/gain at measurement) * (-52.16) * (measured volts)]\u00a0+ 162.08<\/strong><\/p>\n<p>or for degrees Celsius:<\/p>\n<p style=\"padding-left: 30px;\"><strong>deg C\u00a0= [(50\/gain at measurement) * (-28.98) * (measured volts)]\u00a0+\u00a072.26<\/strong><\/p>\n<p>The <a href=\"https:\/\/support.mindwaretech.com\/knowledge-base\/kb0052\/\">recommended gain setting<\/a> for Skin Temperature is <strong>50<\/strong>, so typically<\/p>\n<p style=\"padding-left: 30px;\"><strong>(50\/gain at measurement) = (50\/50) = 1<\/strong><\/p>\n<p>This equation conveniently fits into slope-intercept form (<strong>y = mx + b<\/strong>), one of the scaling types available in BioLab and BSA. Using Fahrenheit as an example, and assuming a gain of 50:<\/p>\n<p style=\"padding-left: 30px;\"><strong>deg F = [(-52.16) * (measured volts)]\u00a0+ 162.08<\/strong><\/p>\n<p>where<\/p>\n<p style=\"padding-left: 30px;\"><strong>y = deg F<br \/>\n<\/strong><strong>x = measured volts<br \/>\n<\/strong><strong>m = -52.16<br \/>\n<\/strong><strong>b = 162.08<\/strong><\/p>\n<h3><em>A note regarding this equation&#8230;<\/em><\/h3>\n<p>Individual probes vary slightly and so this nominal scaling that is useful for detecting temperature changes in a subject throughout a study.<\/p>\n<p>If you need absolute temperature accuracy, you will need to compare it against a calibrated\u00a0thermometer. A quick calibration could be performed by placing the probe and the calibrated thermometer at the same point on a subject and noting the difference between the readings and adding or subtracting the difference from the recorded data. A more involved calibration would involve taking at least two data points using the probe and the thermometer together in various temperature water baths and then scaling the probe data to match the thermometer. For best results, use temperatures that are near the ends\u00a0of the range you plan on measuring.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2>Scaling Skin Temp in BioLab<\/h2>\n<p>First, launch BioLab and locate the channel which the skin temperature probe is connected to. This will always be the last channel on a Transducer module.<\/p>\n<p><a href=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2546\" src=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1.png\" alt=\"\" width=\"1021\" height=\"741\" srcset=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1.png 1021w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1-300x218.png 300w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1-768x557.png 768w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1-50x36.png 50w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1-920x668.png 920w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1-600x435.png 600w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/biolab-config-1-320x232.png 320w\" sizes=\"auto, (max-width: 1021px) 100vw, 1021px\" \/><\/a><\/p>\n<p>Next, press the\u00a0<strong>View Scale<\/strong> button to open the scaling screen.<\/p>\n<p><a href=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2548\" src=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1.png\" alt=\"\" width=\"1020\" height=\"423\" srcset=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1.png 1020w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1-300x124.png 300w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1-768x318.png 768w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1-50x21.png 50w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1-920x382.png 920w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1-600x249.png 600w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Unscaled-1-320x133.png 320w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/><\/a><\/p>\n<p>Notice that the gain is set to 50. Recall the scaling equation from earlier when gain is 50 (we will use Fahrenheit for this example)<\/p>\n<p style=\"padding-left: 30px;\"><strong>deg F = [(-52.16) * (measured volts)]\u00a0+ 162.08<\/strong><\/p>\n<p>Change the scaling type to\u00a0<strong>Slope Intercept<\/strong> and input <strong>m = -52.16<\/strong> and <strong>b = 162.08<\/strong><\/p>\n<p><a href=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2549\" src=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled.png\" alt=\"\" width=\"1020\" height=\"423\" srcset=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled.png 1020w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled-300x124.png 300w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled-768x318.png 768w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled-50x21.png 50w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled-920x382.png 920w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled-600x249.png 600w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Scaled-320x133.png 320w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/><\/a><\/p>\n<p>Finally, change your units to\u00a0<strong>degrees<\/strong><\/p>\n<p><a href=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2550\" src=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees.png\" alt=\"\" width=\"1020\" height=\"423\" srcset=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees.png 1020w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees-300x124.png 300w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees-768x318.png 768w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees-50x21.png 50w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees-920x382.png 920w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees-600x249.png 600w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/Skin-Temp-Degrees-320x133.png 320w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/><\/a><\/p>\n<p>Now your data will be scaled to degrees F during data acquisition. You should see a value of between 90-105 degrees F.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2>Scaling Skin Temp in BSA<\/h2>\n<p>The Basic Signal Analysis application allows you to scale the data in the same way as BioLab. Start by launching the application and selecting the file that contains skin temperature. Once opened, navigate to the Channel Scaling tab.<\/p>\n<p><a href=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2551\" src=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name.png\" alt=\"\" width=\"1014\" height=\"722\" srcset=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name.png 1014w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name-300x214.png 300w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name-768x547.png 768w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name-50x36.png 50w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name-920x655.png 920w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name-600x427.png 600w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Channel-Name-320x228.png 320w\" sizes=\"auto, (max-width: 1014px) 100vw, 1014px\" \/><\/a><\/p>\n<p>Make sure the Skin Temp channel is selected. If you scaled your data in BioLab, the same scaling equation will already be applied.<\/p>\n<p><a href=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2552\" src=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling.png\" alt=\"\" width=\"1014\" height=\"722\" srcset=\"https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling.png 1014w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling-300x214.png 300w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling-768x547.png 768w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling-50x36.png 50w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling-920x655.png 920w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling-600x427.png 600w, https:\/\/support.mindwaretech.com\/wp-content\/uploads\/2017\/04\/BSA-Scaling-320x228.png 320w\" sizes=\"auto, (max-width: 1014px) 100vw, 1014px\" \/><\/a><\/p>\n<p>Otherwise, follow the same steps as in BioLab to scale the skin temperature to the desired units.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The typical skin temperature probe used with MindWare systems requires a modified\u00a0Transducer BioNex module\u00a0to use. \u00a0As with all transducers, the data will initially be displayed in volts. To scale this data to degrees (Fahrenheit or Celsius) \u00a0you need to apply a known scaling equation in either BioLab or the Basic [&hellip;]<\/p>\n","protected":false},"author":2,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"ht-kb-category":[2,101,7,3],"ht-kb-tag":[282,126,280,281,283],"class_list":["post-2543","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-acquisition","ht_kb_category-bsa","ht_kb_category-software","ht_kb_category-analysis","ht_kb_tag-probe","ht_kb_tag-scaling","ht_kb_tag-skin-temp","ht_kb_tag-temperature","ht_kb_tag-transducer"],"_links":{"self":[{"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/ht-kb\/2543","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/comments?post=2543"}],"version-history":[{"count":6,"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/ht-kb\/2543\/revisions"}],"predecessor-version":[{"id":2699,"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/ht-kb\/2543\/revisions\/2699"}],"wp:attachment":[{"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/media?parent=2543"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/ht-kb-category?post=2543"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.mindwaretech.com\/wp-json\/wp\/v2\/ht-kb-tag?post=2543"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}