{"id":66251,"date":"2025-07-13T08:00:00","date_gmt":"2025-07-13T02:30:00","guid":{"rendered":"https:\/\/ye1o34zhk8.onrocket.site\/?p=66251"},"modified":"2025-07-07T16:51:21","modified_gmt":"2025-07-07T11:21:21","slug":"omron-plc-timer-example","status":"publish","type":"post","link":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/","title":{"rendered":"Omron PLC Timer Example Explained"},"content":{"rendered":"\n<p>This article will discuss the use of various <strong>types of timer instructions in the Omron PLC<\/strong>. A timer is an instruction used to delay or control the execution time of an operation in a program. The timer operates based on a predefined duration (preset time). The <a href=\"https:\/\/instrumentationtools.com\/plc-crane-movement-control\/\">CX-Programmer software<\/a> includes four commonly used <strong>timer instructions: TIM, TIMX, TTIM, and TTIMX<\/strong>. To test their use, in this program, each timer instruction will be applied to turn ON a lamp with a specific preset time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-program-objective\">Program Objective<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" width=\"1919\" height=\"1079\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png\" alt=\"PLC Timers with Practical Examples\" class=\"wp-image-66265\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-tim-instruction\">1. TIM Instruction<\/h3>\n\n\n\n<p>The <strong>TIM<\/strong> instruction is a countdown-type timer with a maximum preset time range of 0\u20139999.<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>This instruction counts time in <strong>BCD (Binary Coded Decimal)<\/strong> format, so the preset time parameter must be written with the <strong>&#8220;#&#8221;<\/strong> prefix.<\/li>\n\n\n\n<li>The <a href=\"https:\/\/instrumentationtools.com\/pulse-timer-instruction-in-plc-programming\/\">TIM instruction<\/a> has only one input parameter to activate the instruction and will turn Off if it does not receive a trigger signal.<\/li>\n\n\n\n<li>TIM operates with a time interval of <strong>0.1 seconds (100 ms)<\/strong> and does not retain historical time data.<\/li>\n\n\n\n<li>\u00a0In this program, the timer&#8217;s preset time is set to <strong>10 seconds<\/strong> by writing <strong>#100<\/strong>, and it will turn On <strong>Lamp 1<\/strong>.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-timx-550-instruction\">2. TIMX(550) Instruction<\/h3>\n\n\n\n<p>The <strong>TIMX(550)<\/strong> instruction is a countdown-type timer with a maximum preset time of <strong>0\u201365535<\/strong> in decimal format or <strong>#0000\u2013#FFFF<\/strong> in hexadecimal format.<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>The <a href=\"https:\/\/instrumentationtools.com\/ladder-logic-example-with-timers\/\">preset time<\/a> must begin with an <strong>&#8220;&amp;&#8221;<\/strong> if written in decimal format or with a <strong>&#8220;#&#8221;<\/strong> if written in hexadecimal.<\/li>\n\n\n\n<li>The TIMX instruction has only one input parameter to activate the instruction and will turn Off without a trigger signal.<\/li>\n\n\n\n<li>TIMX has a time interval of <strong>0.1 seconds (100 ms)<\/strong> and cannot store time history.<\/li>\n\n\n\n<li>In this program, the timer is set to <strong>10 seconds<\/strong> using the value &amp;100, and it will turn on <strong>Lamp 2<\/strong>.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-ttim-087-instruction\">3. TTIM(087) Instruction<\/h3>\n\n\n\n<p>The <strong>TTIM(087)<\/strong> instruction is a count-up timer, also known as a <strong>Totalizing Timer<\/strong>, with a maximum preset time of <strong>0\u20139999<\/strong>.<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>This instruction also uses <strong>BCD (Binary Coded Decimal)<\/strong> format, requiring the preset time to be written with the <strong>&#8220;#&#8221;<\/strong> prefix.<\/li>\n\n\n\n<li>TTIM(087) has two input parameters: one to <a href=\"https:\/\/instrumentationtools.com\/jump-instruction-in-siemens-tia-portal\/\">activate the instruction<\/a> and one to reset the stored timer history.<\/li>\n\n\n\n<li>TTIM(087) operates with a <strong>0.1 second (100 ms)<\/strong> interval and can save time history.<\/li>\n\n\n\n<li>In this program, the preset time is set to <strong>10 seconds<\/strong> using #100, and it will turn On <strong>Lamp 3<\/strong>.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-4-ttimx-555-instruction\">4. TTIMX(555) Instruction<\/h3>\n\n\n\n<p>The <strong>TTIMX(555)<\/strong> instruction is a count-up timer, also known as a <strong>Totalizing Timer<\/strong>, with a maximum preset time of <strong>0\u201365535<\/strong> in decimal or <strong>#0000\u2013#FFFF<\/strong> in hexadecimal.<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>The preset value must be prefixed with <strong>&#8220;&amp;&#8221;<\/strong> for decimal or <strong>&#8220;#&#8221;<\/strong> for hexadecimal format.<\/li>\n\n\n\n<li>TTIMX(555) includes two input parameters: one to activate the instruction and one to <a href=\"https:\/\/instrumentationtools.com\/difference-between-timer-and-counter\/\">reset the timer&#8217;s<\/a> stored history.<\/li>\n\n\n\n<li>This timer operates at <strong>0.1 second (100 ms)<\/strong> intervals and can save time history.<\/li>\n\n\n\n<li>In this program, the timer is set to <strong>15 seconds<\/strong> using &amp;150, and it will turn On <strong>Lamp 4<\/strong>.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-omron-plc-timers\">Omron PLC Timers<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" width=\"1961\" height=\"2560\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/Omron-PLC-Timers-scaled.png\" alt=\"Omron PLC Timers\" class=\"wp-image-66262\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-simulation\">Simulation<\/h2>\n\n\n\n<p>In the video below, we simulated this PLC program of various timers and results displayed.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Omron PLC Timers Simulation\" width=\"1240\" height=\"698\" src=\"https:\/\/www.youtube.com\/embed\/JK0KzLpAv70?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-mapping-details\">Mapping Details<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>S.No.<\/th><th>Comment<\/th><th>Input (I)<\/th><th>Output(Q)<\/th><th>Timer<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>TRIG_TIMER1<\/td><td>0.00<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>2<\/td><td>TRIG_TIMER2<\/td><td>0.01<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>3<\/td><td>TRIG_TIMER3<\/td><td>0.02<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>4<\/td><td>RES_TTIM<\/td><td>0.03<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>5<\/td><td>TRIG_TIMER4<\/td><td>0.04<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>6<\/td><td>RES_TTIMX<\/td><td>0.05<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>7<\/td><td>LAMP1<\/td><td>&nbsp;<\/td><td>100.00<\/td><td>&nbsp;<\/td><\/tr><tr><td>8<\/td><td>LAMP2<\/td><td>&nbsp;<\/td><td>100.01<\/td><td>&nbsp;<\/td><\/tr><tr><td>9<\/td><td>LAMP3<\/td><td>&nbsp;<\/td><td>100.02<\/td><td>&nbsp;<\/td><\/tr><tr><td>10<\/td><td>LAMP4<\/td><td>&nbsp;<\/td><td>100.03<\/td><td>&nbsp;<\/td><\/tr><tr><td>11<\/td><td>TIMER_BCD<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>T000<\/td><\/tr><tr><td>12<\/td><td>TIMER_BIN<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>T001<\/td><\/tr><tr><td>13<\/td><td>TIMER_TOTALIZING_BCD<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>T002<\/td><\/tr><tr><td>14<\/td><td>TIMER_TOTALIZING_BIN<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>T003<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-omron-plc-timer-example\">Omron PLC Timer Example<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1027\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/Omron-PLC-Project-Using-Timer-Instruction.png\" alt=\"Omron PLC Project Using Timer Instruction\" class=\"wp-image-66271\"\/><\/figure>\n\n\n\n<p><strong>RUNG 0 (TIMER BCD)<\/strong><\/p>\n\n\n\n<p>In this Rung, if the TRIG_TIMER1 (0.00) button is pressed, then the TIMER_BCD (T000) <a href=\"https:\/\/instrumentationtools.com\/tag\/plc-timer-instruction\/\">timer instruction<\/a> will start counting down for \u201c10\u201d seconds, and when it has finished counting, the TIMER_BCD (T000) timer instruction will be ON.<\/p>\n\n\n\n<p>The TIMER_BCD (T000) timer instruction will be OFF if the TRIG_TIMER1 (0.00) button has been released.<\/p>\n\n\n\n<p><strong>RUNG 1 (OUT TIMER BCD)<\/strong><\/p>\n\n\n\n<p>In this Rung, the LAMP1 (100.00) output will be ON if the NO contact of TIMER_BCD (T000) is in the HIGH state.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1027\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/How-to-Use-TIM-and-TIMX-in-Omron-PLC-Programming.png\" alt=\"How to Use TIM and TIMX in Omron PLC Programming\" class=\"wp-image-66272\"\/><\/figure>\n\n\n\n<p><strong>RUNG 2 (TIMER BIN)<\/strong><\/p>\n\n\n\n<p>In this Rung, if the <a href=\"https:\/\/instrumentationtools.com\/plc-cooking-timer-example\/\">TRIG_TIMER2<\/a> (0.01) button is pressed, then the TIMER_BIN (T001) timer instruction will start counting down for \u201c10\u201d seconds, and when it has finished counting, the TIMER_BIN (T001) timer instruction will be ON.<\/p>\n\n\n\n<p>The TIMER_BIN (T001) timer instruction will be OFF if the TRIG_TIMER2 (0.01) button has been released.<\/p>\n\n\n\n<p><strong>RUNG 3 (OUT TIMER BIN)<\/strong><\/p>\n\n\n\n<p>In this Rung, the LAMP2 (100.01) output will be ON if the NO contact of TIMER_BIN (T001) is in the HIGH state.<\/p>\n\n\n\n<p><strong>RUNG 4 (TIMER TOTALIZING BCD)<\/strong><\/p>\n\n\n\n<p>In this Rung, if the TRIG_TIMER3 (0.02) button is pressed, then the TIMER_TOTALIZING_BCD (T002) timer instruction will start counting up to \u201c10\u201d seconds, and when it has <a href=\"https:\/\/instrumentationtools.com\/plc-programming-for-train-detection\/\">finished counting<\/a>, the TIMER_TOTALIZING_BCD (T002) timer instruction will turn ON.<\/p>\n\n\n\n<p>The TIMER_TOTALIZING_BCD (T002) timer instruction will only turn OFF if the RST_TTIM (0.03) button has been pressed.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1027\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/Practical-Timer-Application-in-Omron-PLC.png\" alt=\"Practical Timer Application in Omron PLC\" class=\"wp-image-66274\"\/><\/figure>\n\n\n\n<p><strong>RUNG 5 (OUT TIMER TOTALIZING BCD)<\/strong><\/p>\n\n\n\n<p>In this Rung, the output LAMP3 (100.02) will be ON if the NO contact of TIMER_BCD (T002) is in the HIGH state.<\/p>\n\n\n\n<p><strong>RUNG 6 (TIMER TOTALIZING BIN)<\/strong><\/p>\n\n\n\n<p>In this Rung, if the TRIG_TIMER4 (0.04) button is pressed, then the TIMER_TOTALIZING_BIN (T003) timer instruction will start counting up to \u201c15\u201d seconds, and when it has finished counting, the <a href=\"https:\/\/instrumentationtools.com\/plc-program-for-flow-totalizer\/\">TIMER_TOTALIZING_BIN<\/a> (T003) timer instruction will be ON.<\/p>\n\n\n\n<p>The TIMER_TOTALIZING_BIN (T003) timer instruction will only be OFF if the RST_TTIMX (0.05) button has been pressed.<\/p>\n\n\n\n<p><strong>RUNG 7 (OUT TIMER TOTALIZING BCD)<\/strong><\/p>\n\n\n\n<p>In this Rung, the LAMP4 (100.03) output will be ON if the NO contact of TIMER_BIN (T003) is in the HIGH state.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/PDF\/PLC\/PDF\/Omron%20PLC%20Timer%20Example.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Omron PLC Timers Project<\/a><\/div>\n<\/div>\n\n\n\n<p><strong>Read Next:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/instrumentationtools.com\/introduction-to-functional-block-diagram-in-studio-5000\/\">Introduction to Functional Block Diagrams<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/instrumentationtools.com\/how-to-insert-block-calls-in-scl-language\/\">How to Insert Block Calls in SCL Language?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/instrumentationtools.com\/for-do-statement-in-scl-language\/\">PLC FOR DO Statement in SCL Language<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/instrumentationtools.com\/automation-system-for-hazardous-environments\/\">Automation System for Hazardous Environments<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/instrumentationtools.com\/mitsubishi-fx3u-plc-with-weinview-hmi\/\">Mitsubishi FX3U PLC with Weinview MT6071iE HMI<\/a><\/li>\n<\/ul>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.<\/p>\n","protected":false},"author":1,"featured_media":66265,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_mo_disable_npp":"","footnotes":""},"categories":[6],"tags":[],"class_list":{"0":"post-66251","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-plc"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Omron PLC Timer Example Explained<\/title>\n<meta name=\"description\" content=\"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Omron PLC Timer Example Explained\" \/>\n<meta property=\"og:description\" content=\"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/\" \/>\n<meta property=\"og:site_name\" content=\"Inst Tools\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/instrumentationtoolss\/\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/instrumentationtoolss\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-13T02:30:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1919\" \/>\n\t<meta property=\"og:image:height\" content=\"1079\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Editorial Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Omron PLC Timer Example Explained\" \/>\n<meta name=\"twitter:description\" content=\"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.\" \/>\n<meta name=\"twitter:creator\" content=\"@insttools\" \/>\n<meta name=\"twitter:site\" content=\"@insttools\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Editorial Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/\"},\"author\":{\"name\":\"Editorial Staff\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/person\\\/41ad3dac301c219e8d41b1ace61655b2\"},\"headline\":\"Omron PLC Timer Example Explained\",\"datePublished\":\"2025-07-13T02:30:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/\"},\"wordCount\":944,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/PLC-Timers-with-Practical-Examples.png\",\"articleSection\":[\"PLC Tutorials\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/\",\"name\":\"Omron PLC Timer Example Explained\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/PLC-Timers-with-Practical-Examples.png\",\"datePublished\":\"2025-07-13T02:30:00+00:00\",\"description\":\"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/PLC-Timers-with-Practical-Examples.png\",\"contentUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/PLC-Timers-with-Practical-Examples.png\",\"width\":1919,\"height\":1079,\"caption\":\"PLC Timers with Practical Examples\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/omron-plc-timer-example\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrumentationtools.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Omron PLC Timer Example Explained\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#website\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/\",\"name\":\"Instrumentation Tools\",\"description\":\"Instrumentation, Electrical, PLC, Tutorials\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\"},\"alternateName\":\"Inst Tools\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrumentationtools.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\",\"name\":\"Instrumentation Tools\",\"alternateName\":\"Inst Tools\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/Instrumentation-Tools-Logo.png\",\"contentUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/Instrumentation-Tools-Logo.png\",\"width\":1024,\"height\":1024,\"caption\":\"Instrumentation Tools\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentationtoolss\\\/\",\"https:\\\/\\\/x.com\\\/insttools\",\"https:\\\/\\\/mastodon.social\\\/@InstrumentationTools\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/instrumentationtools\\\/\",\"https:\\\/\\\/whatsapp.com\\\/channel\\\/0029VaAbUecLNSa4rDPOV31o\",\"https:\\\/\\\/t.me\\\/+u3qORX5FKec1NjA1\",\"https:\\\/\\\/www.instagram.com\\\/instrumentationtools\\\/\",\"https:\\\/\\\/youtube.com\\\/instrumentationtools\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/person\\\/41ad3dac301c219e8d41b1ace61655b2\",\"name\":\"Editorial Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"caption\":\"Editorial Staff\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentationtoolss\",\"https:\\\/\\\/x.com\\\/insttools\",\"https:\\\/\\\/www.youtube.com\\\/c\\\/InstrumentationTools\\\/\"],\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/author\\\/editorial\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Omron PLC Timer Example Explained","description":"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/","og_locale":"en_US","og_type":"article","og_title":"Omron PLC Timer Example Explained","og_description":"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.","og_url":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/","og_site_name":"Inst Tools","article_publisher":"https:\/\/www.facebook.com\/instrumentationtoolss\/","article_author":"https:\/\/www.facebook.com\/instrumentationtoolss","article_published_time":"2025-07-13T02:30:00+00:00","og_image":[{"width":1919,"height":1079,"url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png","type":"image\/png"}],"author":"Editorial Staff","twitter_card":"summary_large_image","twitter_title":"Omron PLC Timer Example Explained","twitter_description":"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.","twitter_creator":"@insttools","twitter_site":"@insttools","twitter_misc":{"Written by":"Editorial Staff","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#article","isPartOf":{"@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/"},"author":{"name":"Editorial Staff","@id":"https:\/\/instrumentationtools.com\/#\/schema\/person\/41ad3dac301c219e8d41b1ace61655b2"},"headline":"Omron PLC Timer Example Explained","datePublished":"2025-07-13T02:30:00+00:00","mainEntityOfPage":{"@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/"},"wordCount":944,"commentCount":0,"publisher":{"@id":"https:\/\/instrumentationtools.com\/#organization"},"image":{"@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png","articleSection":["PLC Tutorials"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/","url":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/","name":"Omron PLC Timer Example Explained","isPartOf":{"@id":"https:\/\/instrumentationtools.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#primaryimage"},"image":{"@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png","datePublished":"2025-07-13T02:30:00+00:00","description":"Dive into the Omron PLC timer example featuring TIM, TIMX, TTIM, and TTIMX instructions for timing-based control applications.","breadcrumb":{"@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrumentationtools.com\/omron-plc-timer-example\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#primaryimage","url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png","contentUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2025\/07\/PLC-Timers-with-Practical-Examples.png","width":1919,"height":1079,"caption":"PLC Timers with Practical Examples"},{"@type":"BreadcrumbList","@id":"https:\/\/instrumentationtools.com\/omron-plc-timer-example\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrumentationtools.com\/"},{"@type":"ListItem","position":2,"name":"Omron PLC Timer Example Explained"}]},{"@type":"WebSite","@id":"https:\/\/instrumentationtools.com\/#website","url":"https:\/\/instrumentationtools.com\/","name":"Instrumentation Tools","description":"Instrumentation, Electrical, PLC, Tutorials","publisher":{"@id":"https:\/\/instrumentationtools.com\/#organization"},"alternateName":"Inst Tools","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrumentationtools.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/instrumentationtools.com\/#organization","name":"Instrumentation Tools","alternateName":"Inst Tools","url":"https:\/\/instrumentationtools.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentationtools.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/10\/Instrumentation-Tools-Logo.png","contentUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/10\/Instrumentation-Tools-Logo.png","width":1024,"height":1024,"caption":"Instrumentation Tools"},"image":{"@id":"https:\/\/instrumentationtools.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/instrumentationtoolss\/","https:\/\/x.com\/insttools","https:\/\/mastodon.social\/@InstrumentationTools","https:\/\/www.linkedin.com\/company\/instrumentationtools\/","https:\/\/whatsapp.com\/channel\/0029VaAbUecLNSa4rDPOV31o","https:\/\/t.me\/+u3qORX5FKec1NjA1","https:\/\/www.instagram.com\/instrumentationtools\/","https:\/\/youtube.com\/instrumentationtools"]},{"@type":"Person","@id":"https:\/\/instrumentationtools.com\/#\/schema\/person\/41ad3dac301c219e8d41b1ace61655b2","name":"Editorial Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","caption":"Editorial Staff"},"sameAs":["https:\/\/www.facebook.com\/instrumentationtoolss","https:\/\/x.com\/insttools","https:\/\/www.youtube.com\/c\/InstrumentationTools\/"],"url":"https:\/\/instrumentationtools.com\/author\/editorial\/"}]}},"_links":{"self":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts\/66251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/comments?post=66251"}],"version-history":[{"count":0,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts\/66251\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/media\/66265"}],"wp:attachment":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/media?parent=66251"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/categories?post=66251"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/tags?post=66251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}