{"id":47065,"date":"2020-03-10T09:24:24","date_gmt":"2020-03-10T03:54:24","guid":{"rendered":"https:\/\/ye1o34zhk8.onrocket.site\/?p=47065"},"modified":"2020-03-10T09:24:24","modified_gmt":"2020-03-10T03:54:24","slug":"question-on-analytical-controller","status":"publish","type":"post","link":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/","title":{"rendered":"Question on Analytical Controller"},"content":{"rendered":"<p>The ratio between base flow and pigment flow in this paint-mixing control system is not fixed. Rather, it comes from the output of an \u201canalytical\u201d controller:<\/p>\n<h2 style=\"text-align: left;\">Analytical Controller<\/h2>\n<p><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-47066 size-full\" title=\"Question on Analytical Controller\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png\" alt=\"Question on Analytical Controller\" width=\"780\" height=\"455\" \/><\/p>\n<p>1. Explain the rationale behind this ratio control system. Also, identify what the \u201cother control system\u201d might be that drives the base<a href=\"https:\/\/instrumentationforum.com\/t\/questions-and-answers-on-control-valves\/7760\" target=\"_blank\" rel=\"noopener noreferrer\"> control valve<\/a>.<\/p>\n<p><strong>Answer:<\/strong><\/p>\n<p style=\"text-align: justify;\">The purpose of this control system is to control the coloring of the paint by analyzing its color using a special instrument, which feeds its color signal to a color controller (AIC), which then automatically adjusts the ratio between base and pigment to achieve the desired output color.<\/p>\n<p style=\"text-align: justify;\">As for the \u201cother control system,\u201d it would most likely be a flow (production) controller.<\/p>\n<p style=\"text-align: justify;\">2. Identify sources of dead time in this process, and which <a href=\"https:\/\/instrumentationtools.com\/4-20-ma-process-control-loops\/\" target=\"_blank\" rel=\"noopener noreferrer\">control loop(s)<\/a> will have to manage despite the presence of dead time.<\/p>\n<p style=\"text-align: justify;\">3. Analyze the effects of the base flowmeter turbine jamming, so that it does not spin even while liquid is still flowing.<\/p>\n<p style=\"text-align: justify;\">4. Analyze the effects of the pigment <a href=\"https:\/\/instrumentationtools.com\/ladder-logic-for-flow-meter-totalizer\/\" target=\"_blank\" rel=\"noopener noreferrer\">flowmeter<\/a> turbine jamming, so that it does not spin even while liquid is still flowing.<\/p>\n<p style=\"text-align: justify;\">5. Assuming the AT outputs a greater signal as the paint becomes more pigmented, determine the correct action for the AIC controller.<\/p>\n<p><span style=\"color: #0000ff;\">Join the Discussion! Share your answers with us through below comments section.<\/span><\/p>\n<h4>Read Next:<\/h4>\n<ul>\n<li><a class=\"LinkSuggestion__Link-sc-1mdih4x-2 jZPuuT\" href=\"https:\/\/instrumentationtools.com\/ziegler-nichols-open-loop-method\/\" target=\"_blank\" rel=\"noopener noreferrer\">Ziegler-Nichols Open-Loop<\/a><\/li>\n<li><a class=\"LinkSuggestion__Link-sc-1mdih4x-2 jZPuuT\" href=\"https:\/\/instrumentationtools.com\/ultrasonic-tank-gauging\/\" target=\"_blank\" rel=\"noopener noreferrer\">Ultrasonic Tank Gauging<\/a><\/li>\n<li><a class=\"LinkSuggestion__Link-sc-1mdih4x-2 jZPuuT\" href=\"https:\/\/instrumentationtools.com\/what-is-a-annunciator-panel\/\" target=\"_blank\" rel=\"noopener noreferrer\">What is Annunciator Panel?<\/a><\/li>\n<li><a class=\"LinkSuggestion__Link-sc-1mdih4x-2 jZPuuT\" href=\"https:\/\/instrumentationtools.com\/distributed-control-system-objective-questions\/\" target=\"_blank\" rel=\"noopener noreferrer\">Distributed Control System<\/a><\/li>\n<li><a class=\"LinkSuggestion__Link-sc-1mdih4x-2 jZPuuT\" href=\"https:\/\/instrumentationtools.com\/why-viscosity-is-not-included-in-the-orifice-equation\/\" target=\"_blank\" rel=\"noopener noreferrer\">What is Orifice equation?<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The ratio between base flow and pigment flow in this paint-mixing control system is not fixed. Rather, it comes from the output of an \u201canalytical\u201d controller: Analytical Controller 1. Explain the rationale behind this ratio control system. Also, identify what the \u201cother control system\u201d might be that drives the base control valve. Answer: The purpose [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":47066,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_mo_disable_npp":"","footnotes":""},"categories":[42328],"tags":[100441],"class_list":{"0":"post-47065","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-question-for-you","8":"tag-analytical-controller"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Question on Analytical Controller - Instrumentation Tools<\/title>\n<meta name=\"description\" content=\"The ratio between base and pigment flows in paint-mixing control system is not fixed. It comes from the output of an analytical controller:\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Question on Analytical Controller - Instrumentation Tools\" \/>\n<meta property=\"og:description\" content=\"The ratio between base and pigment flows in this paint-mixing control system is not fixed. It comes from the output of an analytical controller:\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/\" \/>\n<meta property=\"og:site_name\" content=\"Inst Tools\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/instrumentationtoolss\/\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/instrumentationtoolss\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-10T03:54:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png\" \/>\n\t<meta property=\"og:image:width\" content=\"780\" \/>\n\t<meta property=\"og:image:height\" content=\"455\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Editorial Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Question on Analytical Controller - Instrumentation Tools\" \/>\n<meta name=\"twitter:description\" content=\"The ratio between base and pigment flows in this paint-mixing control system is not fixed. It comes from the output of an analytical controller:\" \/>\n<meta name=\"twitter:creator\" content=\"@insttools\" \/>\n<meta name=\"twitter:site\" content=\"@insttools\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Editorial Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/\"},\"author\":{\"name\":\"Editorial Staff\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/person\\\/41ad3dac301c219e8d41b1ace61655b2\"},\"headline\":\"Question on Analytical Controller\",\"datePublished\":\"2020-03-10T03:54:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/\"},\"wordCount\":235,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Question-on-Analytical-Controller.png\",\"keywords\":[\"Analytical Controller\"],\"articleSection\":[\"Practical Questions\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/\",\"name\":\"Question on Analytical Controller - Instrumentation Tools\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Question-on-Analytical-Controller.png\",\"datePublished\":\"2020-03-10T03:54:24+00:00\",\"description\":\"The ratio between base and pigment flows in paint-mixing control system is not fixed. It comes from the output of an analytical controller:\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Question-on-Analytical-Controller.png\",\"contentUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Question-on-Analytical-Controller.png\",\"width\":780,\"height\":455,\"caption\":\"Question on Analytical Controller\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/question-on-analytical-controller\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrumentationtools.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Question on Analytical Controller\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#website\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/\",\"name\":\"Instrumentation Tools\",\"description\":\"Instrumentation, Electrical, PLC, Tutorials\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\"},\"alternateName\":\"Inst Tools\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrumentationtools.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\",\"name\":\"Instrumentation Tools\",\"alternateName\":\"Inst Tools\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/Instrumentation-Tools-Logo.png\",\"contentUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/Instrumentation-Tools-Logo.png\",\"width\":1024,\"height\":1024,\"caption\":\"Instrumentation Tools\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentationtoolss\\\/\",\"https:\\\/\\\/x.com\\\/insttools\",\"https:\\\/\\\/mastodon.social\\\/@InstrumentationTools\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/instrumentationtools\\\/\",\"https:\\\/\\\/whatsapp.com\\\/channel\\\/0029VaAbUecLNSa4rDPOV31o\",\"https:\\\/\\\/t.me\\\/+u3qORX5FKec1NjA1\",\"https:\\\/\\\/www.instagram.com\\\/instrumentationtools\\\/\",\"https:\\\/\\\/youtube.com\\\/instrumentationtools\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/person\\\/41ad3dac301c219e8d41b1ace61655b2\",\"name\":\"Editorial Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"caption\":\"Editorial Staff\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentationtoolss\",\"https:\\\/\\\/x.com\\\/insttools\",\"https:\\\/\\\/www.youtube.com\\\/c\\\/InstrumentationTools\\\/\"],\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/author\\\/editorial\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Question on Analytical Controller - Instrumentation Tools","description":"The ratio between base and pigment flows in paint-mixing control system is not fixed. It comes from the output of an analytical controller:","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/","og_locale":"en_US","og_type":"article","og_title":"Question on Analytical Controller - Instrumentation Tools","og_description":"The ratio between base and pigment flows in this paint-mixing control system is not fixed. It comes from the output of an analytical controller:","og_url":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/","og_site_name":"Inst Tools","article_publisher":"https:\/\/www.facebook.com\/instrumentationtoolss\/","article_author":"https:\/\/www.facebook.com\/instrumentationtoolss","article_published_time":"2020-03-10T03:54:24+00:00","og_image":[{"width":780,"height":455,"url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png","type":"image\/png"}],"author":"Editorial Staff","twitter_card":"summary_large_image","twitter_title":"Question on Analytical Controller - Instrumentation Tools","twitter_description":"The ratio between base and pigment flows in this paint-mixing control system is not fixed. It comes from the output of an analytical controller:","twitter_creator":"@insttools","twitter_site":"@insttools","twitter_misc":{"Written by":"Editorial Staff","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#article","isPartOf":{"@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/"},"author":{"name":"Editorial Staff","@id":"https:\/\/instrumentationtools.com\/#\/schema\/person\/41ad3dac301c219e8d41b1ace61655b2"},"headline":"Question on Analytical Controller","datePublished":"2020-03-10T03:54:24+00:00","mainEntityOfPage":{"@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/"},"wordCount":235,"commentCount":0,"publisher":{"@id":"https:\/\/instrumentationtools.com\/#organization"},"image":{"@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png","keywords":["Analytical Controller"],"articleSection":["Practical Questions"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/","url":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/","name":"Question on Analytical Controller - Instrumentation Tools","isPartOf":{"@id":"https:\/\/instrumentationtools.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#primaryimage"},"image":{"@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png","datePublished":"2020-03-10T03:54:24+00:00","description":"The ratio between base and pigment flows in paint-mixing control system is not fixed. It comes from the output of an analytical controller:","breadcrumb":{"@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrumentationtools.com\/question-on-analytical-controller\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#primaryimage","url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png","contentUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2020\/03\/Question-on-Analytical-Controller.png","width":780,"height":455,"caption":"Question on Analytical Controller"},{"@type":"BreadcrumbList","@id":"https:\/\/instrumentationtools.com\/question-on-analytical-controller\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrumentationtools.com\/"},{"@type":"ListItem","position":2,"name":"Question on Analytical Controller"}]},{"@type":"WebSite","@id":"https:\/\/instrumentationtools.com\/#website","url":"https:\/\/instrumentationtools.com\/","name":"Instrumentation Tools","description":"Instrumentation, Electrical, PLC, Tutorials","publisher":{"@id":"https:\/\/instrumentationtools.com\/#organization"},"alternateName":"Inst Tools","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrumentationtools.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/instrumentationtools.com\/#organization","name":"Instrumentation Tools","alternateName":"Inst Tools","url":"https:\/\/instrumentationtools.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentationtools.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/10\/Instrumentation-Tools-Logo.png","contentUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/10\/Instrumentation-Tools-Logo.png","width":1024,"height":1024,"caption":"Instrumentation Tools"},"image":{"@id":"https:\/\/instrumentationtools.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/instrumentationtoolss\/","https:\/\/x.com\/insttools","https:\/\/mastodon.social\/@InstrumentationTools","https:\/\/www.linkedin.com\/company\/instrumentationtools\/","https:\/\/whatsapp.com\/channel\/0029VaAbUecLNSa4rDPOV31o","https:\/\/t.me\/+u3qORX5FKec1NjA1","https:\/\/www.instagram.com\/instrumentationtools\/","https:\/\/youtube.com\/instrumentationtools"]},{"@type":"Person","@id":"https:\/\/instrumentationtools.com\/#\/schema\/person\/41ad3dac301c219e8d41b1ace61655b2","name":"Editorial Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","caption":"Editorial Staff"},"sameAs":["https:\/\/www.facebook.com\/instrumentationtoolss","https:\/\/x.com\/insttools","https:\/\/www.youtube.com\/c\/InstrumentationTools\/"],"url":"https:\/\/instrumentationtools.com\/author\/editorial\/"}]}},"_links":{"self":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts\/47065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/comments?post=47065"}],"version-history":[{"count":0,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts\/47065\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/media\/47066"}],"wp:attachment":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/media?parent=47065"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/categories?post=47065"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/tags?post=47065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}