{"id":30142,"date":"2018-07-28T13:58:20","date_gmt":"2018-07-28T08:28:20","guid":{"rendered":"https:\/\/3-inst.toejvy8-liquidwebsites.com\/?p=30142"},"modified":"2018-07-28T13:58:20","modified_gmt":"2018-07-28T08:28:20","slug":"compound-generators","status":"publish","type":"post","link":"https:\/\/instrumentationtools.com\/compound-generators\/","title":{"rendered":"Compound Generators"},"content":{"rendered":"<p style=\"text-align: justify;\"><a href=\"https:\/\/instrumentationtools.com\/series-wound-dc-generators\/\" target=\"_blank\" rel=\"noopener\">Series-wound<\/a> and <a href=\"https:\/\/instrumentationtools.com\/shunt-wound-dc-generators\/\" target=\"_blank\" rel=\"noopener\">shunt-wound<\/a> generators have a disadvantage in that changes in load current cause changes in generator output voltage. Many applications in which generators are used require a more stable output voltage than can be supplied by a series-wound or shuntwound generator. One means of supplying a stable output voltage is by using a compound generator.<\/p>\n<p style=\"text-align: justify;\">The compound generator has a field winding in parallel with the generator armature (the same as a shunt-wound generator) and a field\u00a0winding in series with the generator armature (the same as a series-wound generator) (Figure 12).<\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-30143\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png\" alt=\"Compounded DC Generator\" width=\"1066\" height=\"711\" \/><\/p>\n<p style=\"text-align: center;\">Figure 12 : Compounded DC Generator<\/p>\n<p style=\"text-align: justify;\">The two windings of the compounded generator are made such that their magnetic fields will either aid or oppose one another. If the two fields are wound so that their flux fields oppose one another, the generator is said to be differentially-compounded. Due to the nature of this type of generator, it is used only in special cases and will not be discussed further in this text.<\/p>\n<p style=\"text-align: justify;\">If the two fields of a compound generator are wound so that their magnetic fields aid one another, the generator is said to be cumulatively-compounded. As the load current increases, the current through the series field winding increases, increasing the overall magnetic field strength and causing an increase in the output voltage of the generator. With proper design, the increase in the magnetic field strength of the series winding will compensate for the decrease in shunt field strength.<\/p>\n<p style=\"text-align: justify;\">Therefore, the overall strength of the combined magnetic fields remains almost unchanged, so the output voltage will remain constant. In reality, the two fields cannot be made so that their magnetic field strengths compensate for each other completely. There will be some change in output voltage from the no-load to full-load conditions.<\/p>\n<p style=\"text-align: justify;\">In practical compounded generators, the change in output voltage from no-load to full-load is less than 5 percent. A generator with this characteristic is said to be flat-compounded (Figure 13).<\/p>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-30144\" src=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Voltage-versus-Current-for-a-Compounded-DC-Generator.png\" alt=\"Voltage versus Current for a Compounded DC Generator\" width=\"612\" height=\"446\" \/><\/p>\n<p style=\"text-align: center;\">Figure 13 : Voltage-vs-Current for a Compounded DC Generator<\/p>\n<p style=\"text-align: justify;\">For some applications, the series winding is wound so that it overcompensates for a change in the shunt field. The output gradually rises with increasing load current over the normal operating range of the machine. This type of generator is called an over-compounded generator.<\/p>\n<p style=\"text-align: justify;\">The series winding can also be wound so that it under-compensates for the change in shunt field strength. The output voltage decreases gradually with an increase in load current. This type of generator is called an under-compounded generator.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Series-wound and shunt-wound generators have a disadvantage in that changes in load current cause changes in generator output voltage. Many applications in which generators are used require a more stable output voltage than can be supplied by a series-wound or shuntwound generator. One means of supplying a stable output voltage is by using a compound [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":30143,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_mo_disable_npp":"","footnotes":""},"categories":[52403],"tags":[52793,52794,52804,52806,52784,52776,52783,52782,52781,52777,52779,52778,52780,52798,52799,52797,52792,52785,52796,52807,52786,52789,52788,52803,52802,52790,52801,52791,52800,52795,52805,52787],"class_list":{"0":"post-30142","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-electrical-theory","8":"tag-applications-of-compound-dc-generators","9":"tag-characteristics-of-compound-dc-generators","10":"tag-characteristics-of-compound-wound-dc-generator","11":"tag-characteristics-of-compound-wound-dc-generators","12":"tag-compound-dc-generators","13":"tag-compound-generators","14":"tag-compound-generators-characteristics","15":"tag-compound-generators-in-parallel","16":"tag-compound-generators-operation","17":"tag-compound-generators-principle","18":"tag-compound-generators-theory","19":"tag-compound-generators-working","20":"tag-compound-generators-working-principle","21":"tag-compound-wound-dc-generator","22":"tag-compound-wound-dc-generator-characteristics","23":"tag-compound-wound-dc-generator-principle","24":"tag-compound-wound-dc-generators","25":"tag-compound-wound-generators","26":"tag-compounded-generator","27":"tag-compounded-generators","28":"tag-cross-compound-generators","29":"tag-cumulative-compound-generators","30":"tag-differential-compound-generators","31":"tag-explain-what-dc-compound-wound-generator","32":"tag-function-of-shunt-and-compound-wound-dc-generator","33":"tag-level-compound-generators","34":"tag-long-shunt-compound-wound-dc-generator","35":"tag-over-compound-generators","36":"tag-short-shunt-compound-wound-dc-generator","37":"tag-stability-of-compound-generators-in-parallel","38":"tag-types-of-compound-wound-dc-generator","39":"tag-under-compound-generators"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Compound Generators - Inst Tools<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/instrumentationtools.com\/compound-generators\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Compound Generators\" \/>\n<meta property=\"og:description\" content=\"Series-wound and shunt-wound generators have a disadvantage in that changes in load current cause changes in generator output voltage. Many applications in which generators are used require a more stable output voltage than can be supplied by a series-wound or shuntwound generator. One means of supplying a stable output voltage is by using a compound [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/instrumentationtools.com\/compound-generators\/\" \/>\n<meta property=\"og:site_name\" content=\"Inst Tools\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/instrumentationtoolss\/\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/instrumentationtoolss\" \/>\n<meta property=\"article:published_time\" content=\"2018-07-28T08:28:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1066\" \/>\n\t<meta property=\"og:image:height\" content=\"711\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Editorial Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@insttools\" \/>\n<meta name=\"twitter:site\" content=\"@insttools\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Editorial Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/\"},\"author\":{\"name\":\"Editorial Staff\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/person\\\/41ad3dac301c219e8d41b1ace61655b2\"},\"headline\":\"Compound Generators\",\"datePublished\":\"2018-07-28T08:28:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/\"},\"wordCount\":412,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Compounded-DC-Generator.png\",\"keywords\":[\"applications of compound dc generators\",\"characteristics of compound dc generators\",\"characteristics of compound wound dc generator\",\"characteristics of compound wound dc generators\",\"compound dc generators\",\"Compound Generators\",\"compound generators characteristics\",\"compound generators in parallel\",\"Compound Generators Operation\",\"Compound Generators Principle\",\"Compound Generators Theory\",\"Compound Generators Working\",\"Compound Generators Working Principle\",\"compound wound dc generator\",\"compound wound dc generator characteristics\",\"compound wound dc generator principle\",\"compound wound dc generators\",\"compound wound generators\",\"compounded generator\",\"compounded generators\",\"cross compound generators\",\"cumulative compound generators\",\"differential compound generators\",\"explain what dc compound wound generator\",\"function of shunt and compound wound dc generator\",\"level compound generators\",\"long shunt compound wound dc generator\",\"over compound generators\",\"short shunt compound wound dc generator\",\"stability of compound generators in parallel\",\"types of compound wound dc generator\",\"under compound generators\"],\"articleSection\":[\"Electrical Theory\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/\",\"name\":\"Compound Generators - Inst Tools\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Compounded-DC-Generator.png\",\"datePublished\":\"2018-07-28T08:28:20+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#primaryimage\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Compounded-DC-Generator.png\",\"contentUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Compounded-DC-Generator.png\",\"width\":1066,\"height\":711,\"caption\":\"Compounded DC Generator\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/compound-generators\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/instrumentationtools.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Compound Generators\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#website\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/\",\"name\":\"Instrumentation Tools\",\"description\":\"Instrumentation, Electrical, PLC, Tutorials\",\"publisher\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\"},\"alternateName\":\"Inst Tools\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/instrumentationtools.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#organization\",\"name\":\"Instrumentation Tools\",\"alternateName\":\"Inst Tools\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/Instrumentation-Tools-Logo.png\",\"contentUrl\":\"https:\\\/\\\/instrumentationtools.com\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/Instrumentation-Tools-Logo.png\",\"width\":1024,\"height\":1024,\"caption\":\"Instrumentation Tools\"},\"image\":{\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentationtoolss\\\/\",\"https:\\\/\\\/x.com\\\/insttools\",\"https:\\\/\\\/mastodon.social\\\/@InstrumentationTools\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/instrumentationtools\\\/\",\"https:\\\/\\\/whatsapp.com\\\/channel\\\/0029VaAbUecLNSa4rDPOV31o\",\"https:\\\/\\\/t.me\\\/+u3qORX5FKec1NjA1\",\"https:\\\/\\\/www.instagram.com\\\/instrumentationtools\\\/\",\"https:\\\/\\\/youtube.com\\\/instrumentationtools\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/instrumentationtools.com\\\/#\\\/schema\\\/person\\\/41ad3dac301c219e8d41b1ace61655b2\",\"name\":\"Editorial Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g\",\"caption\":\"Editorial Staff\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/instrumentationtoolss\",\"https:\\\/\\\/x.com\\\/insttools\",\"https:\\\/\\\/www.youtube.com\\\/c\\\/InstrumentationTools\\\/\"],\"url\":\"https:\\\/\\\/instrumentationtools.com\\\/author\\\/editorial\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Compound Generators - Inst Tools","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/instrumentationtools.com\/compound-generators\/","og_locale":"en_US","og_type":"article","og_title":"Compound Generators","og_description":"Series-wound and shunt-wound generators have a disadvantage in that changes in load current cause changes in generator output voltage. Many applications in which generators are used require a more stable output voltage than can be supplied by a series-wound or shuntwound generator. One means of supplying a stable output voltage is by using a compound [&hellip;]","og_url":"https:\/\/instrumentationtools.com\/compound-generators\/","og_site_name":"Inst Tools","article_publisher":"https:\/\/www.facebook.com\/instrumentationtoolss\/","article_author":"https:\/\/www.facebook.com\/instrumentationtoolss","article_published_time":"2018-07-28T08:28:20+00:00","og_image":[{"width":1066,"height":711,"url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png","type":"image\/png"}],"author":"Editorial Staff","twitter_card":"summary_large_image","twitter_creator":"@insttools","twitter_site":"@insttools","twitter_misc":{"Written by":"Editorial Staff","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/instrumentationtools.com\/compound-generators\/#article","isPartOf":{"@id":"https:\/\/instrumentationtools.com\/compound-generators\/"},"author":{"name":"Editorial Staff","@id":"https:\/\/instrumentationtools.com\/#\/schema\/person\/41ad3dac301c219e8d41b1ace61655b2"},"headline":"Compound Generators","datePublished":"2018-07-28T08:28:20+00:00","mainEntityOfPage":{"@id":"https:\/\/instrumentationtools.com\/compound-generators\/"},"wordCount":412,"commentCount":0,"publisher":{"@id":"https:\/\/instrumentationtools.com\/#organization"},"image":{"@id":"https:\/\/instrumentationtools.com\/compound-generators\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png","keywords":["applications of compound dc generators","characteristics of compound dc generators","characteristics of compound wound dc generator","characteristics of compound wound dc generators","compound dc generators","Compound Generators","compound generators characteristics","compound generators in parallel","Compound Generators Operation","Compound Generators Principle","Compound Generators Theory","Compound Generators Working","Compound Generators Working Principle","compound wound dc generator","compound wound dc generator characteristics","compound wound dc generator principle","compound wound dc generators","compound wound generators","compounded generator","compounded generators","cross compound generators","cumulative compound generators","differential compound generators","explain what dc compound wound generator","function of shunt and compound wound dc generator","level compound generators","long shunt compound wound dc generator","over compound generators","short shunt compound wound dc generator","stability of compound generators in parallel","types of compound wound dc generator","under compound generators"],"articleSection":["Electrical Theory"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/instrumentationtools.com\/compound-generators\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/instrumentationtools.com\/compound-generators\/","url":"https:\/\/instrumentationtools.com\/compound-generators\/","name":"Compound Generators - Inst Tools","isPartOf":{"@id":"https:\/\/instrumentationtools.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/instrumentationtools.com\/compound-generators\/#primaryimage"},"image":{"@id":"https:\/\/instrumentationtools.com\/compound-generators\/#primaryimage"},"thumbnailUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png","datePublished":"2018-07-28T08:28:20+00:00","breadcrumb":{"@id":"https:\/\/instrumentationtools.com\/compound-generators\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/instrumentationtools.com\/compound-generators\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentationtools.com\/compound-generators\/#primaryimage","url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png","contentUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/07\/Compounded-DC-Generator.png","width":1066,"height":711,"caption":"Compounded DC Generator"},{"@type":"BreadcrumbList","@id":"https:\/\/instrumentationtools.com\/compound-generators\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/instrumentationtools.com\/"},{"@type":"ListItem","position":2,"name":"Compound Generators"}]},{"@type":"WebSite","@id":"https:\/\/instrumentationtools.com\/#website","url":"https:\/\/instrumentationtools.com\/","name":"Instrumentation Tools","description":"Instrumentation, Electrical, PLC, Tutorials","publisher":{"@id":"https:\/\/instrumentationtools.com\/#organization"},"alternateName":"Inst Tools","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/instrumentationtools.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/instrumentationtools.com\/#organization","name":"Instrumentation Tools","alternateName":"Inst Tools","url":"https:\/\/instrumentationtools.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/instrumentationtools.com\/#\/schema\/logo\/image\/","url":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/10\/Instrumentation-Tools-Logo.png","contentUrl":"https:\/\/instrumentationtools.com\/wp-content\/uploads\/2018\/10\/Instrumentation-Tools-Logo.png","width":1024,"height":1024,"caption":"Instrumentation Tools"},"image":{"@id":"https:\/\/instrumentationtools.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/instrumentationtoolss\/","https:\/\/x.com\/insttools","https:\/\/mastodon.social\/@InstrumentationTools","https:\/\/www.linkedin.com\/company\/instrumentationtools\/","https:\/\/whatsapp.com\/channel\/0029VaAbUecLNSa4rDPOV31o","https:\/\/t.me\/+u3qORX5FKec1NjA1","https:\/\/www.instagram.com\/instrumentationtools\/","https:\/\/youtube.com\/instrumentationtools"]},{"@type":"Person","@id":"https:\/\/instrumentationtools.com\/#\/schema\/person\/41ad3dac301c219e8d41b1ace61655b2","name":"Editorial Staff","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7d7b78a0bf6b95aebc68e7790f9094403ae40b3fcb9c436cb6956873b90826de?s=96&d=mm&r=g","caption":"Editorial Staff"},"sameAs":["https:\/\/www.facebook.com\/instrumentationtoolss","https:\/\/x.com\/insttools","https:\/\/www.youtube.com\/c\/InstrumentationTools\/"],"url":"https:\/\/instrumentationtools.com\/author\/editorial\/"}]}},"_links":{"self":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts\/30142","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/comments?post=30142"}],"version-history":[{"count":0,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/posts\/30142\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/media\/30143"}],"wp:attachment":[{"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/media?parent=30142"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/categories?post=30142"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/instrumentationtools.com\/wp-json\/wp\/v2\/tags?post=30142"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}