- All designs are fabricated and tested
- Contains hierarchical schematic, documentation, parameterized Hspice netlist and sanitized CDL netlist.
- The known good design (KGD) IPs that are illustrated in the following table can be found in the folder AMS_KGD
| Circuit | Architecture | Design File Location |
|---|---|---|
| SAR_ADC | 12b SAR ADC | AMS_KGD/SAR_ADC |
| DLDO | Digital LDO | AMS_KGD/DLDO |
| MDLL | Multiplying DLL | AMS_KGD/MDLL |
| TX | Transmitter | AMS_KGD/Transmitter |
| TS | Temperature Sensor | AMS_KGD/TempSensor |
-
The modules that build up the above circuits are included in the folder Module.
-
The modules for the SAR ADC
-
The modules for the transmitter
-
The modules for the temperature sensor