For detailes on the library usage visit documentation section.
//modbusRTU_pico_example.ino
#include "ModbusRTU_PICO.h"
#define MODBUS_SLAVE_ID 1
#define REG_TEMPERATURE 0 // 温度×10 寄存器地址
#define REG_HUMIDITY 1 // 湿度×10 寄存器地址
ModbusRTU mb;
// 模拟温湿度数据(存储在寄存器中)
uint16_t temperature = 256; // 25.6℃(放大10倍存储)
uint16_t humidity = 605; // 60.5%(放大10倍存储)
void setup() {
// 初始化 Modbus 从站
Serial.begin(9600, SERIAL_8N1);
mb.begin(&Serial);
//mb.setBaudrate(9600);
mb.slave(MODBUS_SLAVE_ID);
mb.addHreg(REG_TEMPERATURE);
mb.addHreg(REG_HUMIDITY);
}
void loop() {
// 模拟数据更新(每1秒更新一次温湿度)
static uint32_t lastUpdate = 0;
if (millis() - lastUpdate >= 2000) {
lastUpdate = millis();
// 温度随机波动±0.5℃
temperature = constrain(temperature + (random(-5, 6)), 200, 300);
// 湿度随机波动±0.5%
humidity = constrain(humidity + (random(-5, 6)), 500, 700);
// 更新寄存器
mb.Hreg(REG_TEMPERATURE, temperature);
mb.Hreg(REG_HUMIDITY, humidity);
// 调试输出
//Serial1.printf("Temperature: %.1f℃, Humidity: %.1f%%\n",
// temperature/10.0, humidity/10.0);
}
//delay(1);
mb.task();
}
- Supports all Arduino platforms
- Operates in any combination of multiple instances of
- Modbus RTU server
- Modbus RTU client
- Modbus TCP server for ESP8266/ESP32 and Ethernet library
- Modbus TCP client for ESP8266/ESP32 and Ethernet library
- MODBUS/TCP Security server (ESP8266)
- MODBUS/TCP Security client (ESP8266/ESP32)
- Modbus functions supported:
- 0x01 - Read Coils
- 0x02 - Read Input Status (Read Discrete Inputs)
- 0x03 - Read Holding Registers
- 0x04 - Read Input Registers
- 0x05 - Write Single Coil
- 0x06 - Write Single Register
- 0x0F - Write Multiple Coils
- 0x10 - Write Multiple Registers
- 0x14 - Read File Record
- 0x15 - Write File Record
- 0x16 - Mask Write Register
- 0x17 - Read/Write multiple registers
- Callbacks driven design
- Real life complex examples:
- The offsets for registers are 0-based. So be careful when setting your supervisory system or your testing software. For example, in ScadaBR offsets are 0-based, then, a register configured as 100 in the library is set to 100 in ScadaBR. On the other hand, in the CAS Modbus Scanner offsets are 1-based, so a register configured as 100 in library should be 101 in this software.
- RS-485 transivers based on MAX-485 is working on at least up to 115200. XY-017/XY-485 working only up to 9600 for some reason.
For more information about Modbus see:
- Modbus (From Wikipedia, the free encyclopedia)
- MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3
- MODBUS MESSAGING ON TCP/IP IMPLEMENTATION GUIDE V1.0b
- MODBUS over Serial Line Specification and Implementation Guide V1.02
- MODBUS/TCP Security Protocol Specification
// 4.1.0
+ API: Raw Modbus frame processing functionality
+ ModbusRTU: Precise inter-frame interval control
+ Examples: True ModbusRTU to ModbusTCP Server bridge
+ Examples: ModbusRTU respond to multiple ID from single device
+ ModbusRTU: Add direction control pin for Stream
+ STL: Add Reg count limitation to vector limit of 4000 (for ESP8266 and ESP32)
+ Settings: Added MODBUSIP_CONNECTION_TIMEOUT (ESP32 only)
+ Settings: Set MODBUSIP_MAX_CLIENTS = 8 for ESP32
+ ModbusTCP: Make using DNS names optional feature
+ ModbusRTU: Add separate RE/DE pins control optional feature
+ API: Drop support of Ethernet library v1
+ Examples: Teknic ClearCore ArduinoWrapper examples added
+ Examples: ModbusTCP to ModbusRTU example added
+ ModbusRTU: Flush extra delay optional feature
// 4.0.0
+ Support of all Arduino boards
+ ModbusTLS: ESP8266 Client/Server and ESP32 Client
+ ModbusTCP: ModbusEthernet - WizNet W5x00, ENC28J60 Ethernet library support
+ 0x14 - Read File Records function
+ 0x15 - Write File Records function
+ Examples: FW update over Modbus fullfunctional example
+ 0x16 - Write Mask Register function+ Test: 0x16
+ 0x17 - Read/Write Registers function
+ ModbusRTU: ESP32 SoftwareSerial support
+ Build with no STL dependency (switchable)
+ API: ModbusIP => ModbusTCP
+ API: Access control callback for individual Modbus function
+ API: Master/Slave => Client/Server according to [PRESS RELEASE](https://modbus.org/docs/Client-ServerPR-07-2020-final.docx.pdf)
+ Lot of code refacting and small fixes// 4.2.0-DEV
- API: Alternative CRC calulation (reduced memory footprint)
- ModbusRTU: Static buffer allocation
- Test: Frame accuracy to specefication
- Buffer/packet size limitation support
- Slave/Server: slavePDU use early exit by return where possible
- Master/Client: Check frame size against header data where possible
- Master/Client: Additional responce data validation
- Free global registers and callbacks on remove last Modbus instance
- Test: push/pull functions
- ModbusTCP: Refactor connect by dns name (using native implementation for ESP32 etc)
// 4.3.0-DEV
- ModbusTLS: ESP32 Server
- Test: TLS ESP32 Server
- Test: TLS ESP32 Client
- Examples: TLS Certificate test Role extension and Alt-Name
- Examples: TLS Add example explanation
- ModbusTCP: ModbusAsyncTCP
- API: Extend API to allow custom Modbus commands
- Examples: Basic file operations
- Examples: Revisinghttps://github.com/emelianov/modbus-esp8266
Original version:
https://github.com/andresarmento/modbus-esp8266
https://github.com/andresarmento/modbus-arduino
prof (at) andresarmento (dot) com
The code in this repo is licensed under the BSD New License. See LICENSE.txt for more info.