Skip to content

Conversation

@YooSunYoung
Copy link
Member

No description provided.

@YooSunYoung YooSunYoung requested a review from nvaytet June 23, 2025 15:55
Comment on lines +230 to +241
.. note::
`factor` should correct the different neutron flux
between the sample and the background.
For example, if the open beam(background) image
is taken with longer exposure time
than the sample image with the same neutron rate,
the scale factor should be larger than 1.
The scale factor could be derived from the exposure time,
proton charge or monitor counts depending on the experiment.
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I wonder why the sample and background images don't get normalized first, so the scale factor is avoided?

Copy link
Member Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

You can do that. It was easier this way to replace the scale factor by hand if needed.

@YooSunYoung YooSunYoung merged commit bb3e4de into main Jun 24, 2025
4 checks passed
@YooSunYoung YooSunYoung deleted the docstring branch June 24, 2025 17:05
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment