ModbusRTU

Description

Library for ModbusRTU communication protocol support which is able to run synchronously with main thread. Modbus is communication protocol based on 16-bit registers. Rtu version uses serial line (here, RTU means real-time UART). This ModbusRtu library is ultra light, so it implements only ReadInputRegisters, ReadHoldingRegisters and WriteSingleRegister functions on server and client side, and WriteMultipleRegisters only on client side. Due to it's lightweight nature, it does not take much computational power. Thus it can run on single-core CPUs with relatively low frequency (i.e. Arduino Uno) without significal inpact on main program performance.

Usage

Minimal setup

Basic communication

Library uses default serial port for communication. Default settings are:

  • 8 bit transmission
  • 1 parity bit (even parity)
  • 1 stop bit

These settings are required by ModbusRTU specification.

User should pick one of the classes - ModbusRTUServer or ModbusRTUClient, according to their requirements. The base ModbusRTU class serves only as a common interface for data transmission.

Basic functions - Server

To initialize Modbus server, call startModbusServer function with specified device address and baud rate. If no serial port has been specified, default one will be initialized and used for communication.

To read and write values from/to specific registers, use setInputValue, setHoldingValue and getHoldingValue functions with specified register address.

To read and write bulks of datas, use copyToInputRegisters, copyToHoldingRegisters and copyFromHoldingRegisters functions. These function require buffer to copy data from/to, number of copied registers and address of first register.

To operate modbus server, call communicationLoop function in main program loop. This function returns true if new data have been received (WriteSingleRegister function), false otherwise

Basic functions - Client

To initialize Modbus client, call startModbusClient function with specified device address and baud rate. If no serial port has been specified, default one will be initialized and used for communication.

To read values from registers, use readInputRegisters and readHoldingRegisters functions.

To write data into registers, use writeSingleRegister and writeMultipleRegisters functions.

Optionally, user can decide whether should Modbus exception be considered as a valid response. In that case, exception code is retained from request which caused it. Also, user can specify timeout between request and respone (default is 200 ms).

Additional settings

UART port configuration

If the device contains more serial UART communication interfaces, user can specify which one will be used by providing it as a parameter to startModbusServer or startModbusClient function.

Additionally, if user wants to initialize serial port manually (perhaps with custom settings), they may set parameter initialize of startModbus... function to false. In this case, user is responsible for initialising the serial port before calling this function.

Custom buffer definition

In case user wants to use the custom register buffer for server instead of the default one, they can specify one using setInputRegisteBuffer function. Similar applies for holding register (setHoldingRegisterBuffer function). These buffers must be able to hold unsigned 16-bit values.

Additionally USE_EXTERNAL_INPUT_REGISTER_BUFFER, resp. USE_EXTERNAL_HOLDING_REGISTER_BUFFER must be set to true. NOTE: This setting can also be used if only client-side library will be used. In that case, default buffers will not be created, which will save some memory.

In case the user wants to use the default register buffers, but with different size, they can modify INPUT_REGISTER_NUM and HOLDING_REGISTER_NUM defines.

By default, variable length buffer for raw data will be used each time the response is constructed (in case of server) or read (in case of client). In case user wants to fix the size of this buffer, they may set USE_FIXED_SCRATCH_BUFFER_SIZE define to true. In this case, SCRATCH_BUFFER_SIZE define must be set to specify response buffer size. The size must be at least 8 bytes.

Custom read/write functions

To use custom function to read/write from/to a serial port, use setSerialReadFunction and setSerialWriteFunction. The custom function must accept these parameters:

  • buffer where to store request/response

  • length of buffer (number of bytes to send or number of bytes to read)

  • context - a void pointer used to pass custom function all the data user decides to pass it

    The context can be anything, f.e. a structure containig serial port handler

The write function return value is void. The read function value is number of read bytes, or 0 if nothing usable was received.

Additionally, USE_CUSTOM_READ_WRITE_FUNCTIONS must be set to true

Timestamp function

By default, micros function is called to obtain current timestamp. This can be altered by modifying GET_TIMESTAMP_US define. The timestamp function mus return the value in microseconds, in uint32_t format.

Request callbacks (server only)

Library supports user-defined callbacks which are called when specific request is received.

To set callback for ReadInputRegisters request, use setReadInputRegistersCallback function. This callback is called right before the response is sent.

To set callback for ReadHoldingRegisters request, use setReadHoldingRegistersCallback function. This callback is called right before the response is sent.

To set callback for WriteSingleRegister request, use setWriteHoldingRegisterCallback function. This callback is called right after the request is received, before data are stored in specified register.

Each callback function must accept these parameters:

  • buffer with request/response data
  • length of the buffer
  • context - a void pointer used to pass custom function all the data user decides to pass it

To register function as a callback, use the corresponding set...Callback function. The context parameter can be used to pass any data user wants to the callback function.

Implementation limits and further usage

Server-side library is set to accept only one request at a time. Additionally, the request must be 8 bytes long. This may be drawbacks for some use cases, but it enables further optimization. For example, DMA can be used to transfer data from serial buffer. Also, no time is wasted by polling serial line for potential data, when size of the packet is unknown.

There is also timeout for transaction (from the first byte to the last one), so if the data are not fully received within specified time, they are discarded. This way, the buffer is not getiting clogged with fragments of messages.

Although library was build using Arduino framework, it is possible to use it even outside Arduino environment (see Custom read/write functions and Timestamp functions).

About

Library for ModbusRtu, which uses serial line (UART) and is able to run synchronously with main thread.