Notifications
You must be signed in to change notification settings - Fork 11.1k
Multiple h2_full_nosec_test tests failed on windows-worker3 with possible port server issues #12595
Copy link
Copy link
Closed
Description
It looks like this test failed to reach a server:
c_windows_opt_native.cmake/build/Release/h2_full_nosec_test.exe filter_call_init_fails
shows output:
D0915 02:38:03.161000000 1932 test_config.c:388] test slowdown factor: sanitizer=1, fixture=1, poller=1, total=1
D0915 02:38:03.163000000 1932 dns_resolver.c:301] Using native dns resolver
I0915 02:38:03.163000000 1932 filter_call_init_fails.c:513] Testing SERVER_CHANNEL filter.
I0915 02:38:03.163000000 1932 filter_call_init_fails.c:48] Running test: filter_call_init_fails/chttp2/fullstack
I0915 02:38:03.719000000 1932 filter_call_init_fails.c:517] Testing CLIENT_CHANNEL / CLIENT_DIRECT_CHANNEL filter.
I0915 02:38:03.719000000 1932 filter_call_init_fails.c:48] Running test: filter_call_init_fails/chttp2/fullstack
E0915 02:38:04.754000000 1932 channel.c:295] call_create: {"created":"@1505443084.754000000","description":"Call creation failed","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\surface\call.c","file_line":299,"referenced_errors":[{"created":"@1505443084.754000000","description":"access denied","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\test\core\end2end\tests\filter_call_init_fails.c","file_line":406,"grpc_status":7}]}
I0915 02:38:04.755000000 1932 filter_call_init_fails.c:522] Testing CLIENT_SUBCHANNEL filter.
I0915 02:38:04.755000000 1932 filter_call_init_fails.c:48] Running test: filter_call_init_fails/chttp2/fullstack
D0915 02:38:06.780000000 1932 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443086.780000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443085.780000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443085.780000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443086.780000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:09.950000000 1932 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443089.950000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443088.935000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443088.935000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443089.950000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
E0915 02:38:12.174000000 1932 filter_call_init_fails.c:354] assertion failed: status == GRPC_STATUS_PERMISSION_DENIED
Abort handler called.
*** 0: 0000000001422EBC - 0000000000000000
*** 1: 0000000001422B0D - 0000000000000000
*** 2: 000000006DC44672 abort - 000000006DC44640
*** 3: 00000000013BB3F6 abort - 000000006DC44640
*** 4: 00000000013BAA12 abort - 000000006DC44640
*** 5: 00000000013B1CB4 abort - 000000006DC44640
*** 6: 00000000013B118F abort - 000000006DC44640
*** 7: 000000000142D076 abort - 000000006DC44640
*** 8: 0000000076A5336A BaseThreadInitThunk - 0000000076A53358
*** 9: 0000000076F89902 RtlInitializeExceptionChain - 0000000076F8989F
*** 10: 0000000076F898D5 RtlInitializeExceptionChain - 0000000076F8989F
Other tests on the same machine look like they have possibly related errors:
c_windows_opt_native.cmake/build/Release/h2_full_test.exe ping_pong_streaming
shows output:
Failure
Stacktrace
c:38] Running test: test_pingpong_streaming/chttp2/fullstack
I0915 02:37:49.617000000 8292 ping_pong_streaming.c:38] Running test: test_pingpong_streaming/chttp2/fullstack
I0915 02:37:49.680000000 8292 ping_pong_streaming.c:38] Running test: test_pingpong_streaming/chttp2/fullstack
I0915 02:37:50.323000000 8292 ping_pong_streaming.c:38] Running test: test_pingpong_streaming/chttp2/fullstack
D0915 02:37:52.379000000 8292 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443072.379000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443071.348000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443071.348000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443072.379000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:37:55.504000000 8292 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443075.504000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443074.449000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443074.449000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443075.504000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:37:59.217000000 8292 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443079.217000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443078.216000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443078.216000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443079.217000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:02.812000000 8292 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443082.812000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443081.812000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443081.812000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443082.812000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:07.367000000 8292 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443087.367000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443086.272000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443086.272000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443087.367000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:11.080000000 8292 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443091.080000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443090.058000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443090.058000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443091.080000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
gRPC tests require a helper port server to allocate ports used
during the test.
This server is not currently running.
To start it, run tools/run_tests/start_port_server.py
And
c_windows_opt_native.cmake/build/Release/h2_ssl_cert_test.exe simple_cacheable_request
shows output:
Failure
Stacktrace
D0915 02:37:50.454000000 3536 test_config.c:388] test slowdown factor: sanitizer=1, fixture=1, poller=1, total=1
D0915 02:37:50.456000000 3536 dns_resolver.c:301] Using native dns resolver
I0915 02:37:50.456000000 3536 h2_ssl_cert.c:256] SSL_CERT_tests/chttp2/ssl_GRPC_SSL_DONT_REQUEST_CLIENT_CERTIFICATE_NONE_SUCCESS_
D0915 02:37:52.866000000 3536 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443072.866000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443071.783000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443071.783000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443072.866000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:37:56.079000000 3536 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443076.079000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443075.066000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443075.066000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443076.079000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:37:59.749000000 3536 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443079.749000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443078.679000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443078.679000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443079.749000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:03.488000000 3536 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443083.488000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443082.411000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443082.411000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443083.488000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:07.989000000 3536 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443087.989000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443086.905000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443086.905000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443087.989000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
D0915 02:38:11.389000000 3536 port_server_client.c:140] failed port pick from server: retrying [{"created":"@1505443091.389000000","description":"Failed HTTP requests to all targets","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":213,"referenced_errors":[{"created":"@1505443090.379000000","description":"Failed HTTP/1 client request","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\http\httpcli.c","file_line":116,"referenced_errors":[{"created":"@1505443090.379000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv4:127.0.0.1:32766","wsa_error":10061},{"created":"@1505443091.389000000","description":"OS Error","file":"C:\jenkins\workspace\gRPC_pr_win\workspace_c_windows_opt_native\src\core\lib\iomgr\tcp_client_windows.c","file_line":105,"os_error":"No connection could be made because the target machine actively refused it.\r\n","syscall":"ConnectEx","target_address":"ipv6:[::1]:32766","wsa_error":10061}]}]}]
gRPC tests require a helper port server to allocate ports used
during the test.
This server is not currently running.
To start it, run tools/run_tests/start_port_server.py
jenkins main page in https://grpc-testing.appspot.com/job/gRPC_pr_win/7833/#showFailuresLink
What's strange though is that making a GET request to http://localhost:32766/version_number on grpc-jenkins-windows-worker3 shows 20, so it looks like that the worker is running the latest master's version of the port server as intended.
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
No labels