Gradle Version
8.11.1
AGP Version
8.7.3
Code Minifier/Optimizer
None
Version
4.14.1
Sentry SDK Version
7.18.0
Steps to Reproduce
Use the Sentry auto-init feature:
- Apply sentry gradle plugin
4.14.1
- Set the sample-rate in the
AndroidManifest.xml: <meta-data android:name="io.sentry.traces.sample-rate" android:value="1.0" />
- Run the appplication in debug
- Check Logcat filtering for "Sentry" word
The issue started from 4.14.0. The version 4.13.0 is working as expected. This PR is probably the cause of the issue.
Expected Result
Successfully init the App with the Sentry configuration. The logcat will show only io.sentry.auto-init read: true when filtering for "Sentry" word.
Actual Result
The Logcat shows io.sentry.auto-init read: true and then warning messages related to the manifest configuration of float values:
Key io.sentry.traces.sample-rate expected Integer but value was a java.lang.Float. The default value -1 was returned.
Attempt to cast generated internal exception:
java.lang.ClassCastException: java.lang.Float cannot be cast to java.lang.Integer
at android.os.BaseBundle.getInt(BaseBundle.java:1050)
at io.sentry.android.core.ManifestMetadataReader.readDouble(ManifestMetadataReader.java:500)
at io.sentry.android.core.ManifestMetadataReader.applyMetadata(ManifestMetadataReader.java:294)
at io.sentry.android.core.AndroidOptionsInitializer.loadDefaultAndMetadataOptions(AndroidOptionsInitializer.java:109)
at io.sentry.android.core.SentryAndroid.lambda$init$1(SentryAndroid.java:116)
at io.sentry.android.core.SentryAndroid$$ExternalSyntheticLambda0.configure(D8$$SyntheticClass:0)
at io.sentry.Sentry.applyOptionsConfiguration(Sentry.java:196)
at io.sentry.Sentry.init(Sentry.java:166)
at io.sentry.android.core.SentryAndroid.init(SentryAndroid.java:93)
at io.sentry.android.core.SentryAndroid.init(SentryAndroid.java:64)
at io.sentry.android.core.SentryInitProvider.onCreate(SentryInitProvider.java:25)
at android.content.ContentProvider.attachInfo(ContentProvider.java:2117)
at android.content.ContentProvider.attachInfo(ContentProvider.java:2091)
at io.sentry.android.core.SentryInitProvider.attachInfo(SentryInitProvider.java:43)
at android.app.ActivityThread.installProvider(ActivityThread.java:7187)
at android.app.ActivityThread.installContentProviders(ActivityThread.java:6670)
at android.app.ActivityThread.handleBindApplication(ActivityThread.java:6565)
at android.app.ActivityThread.access$1400(ActivityThread.java:224)
at android.app.ActivityThread$H.handleMessage(ActivityThread.java:1887)
at android.os.Handler.dispatchMessage(Handler.java:107)
at android.os.Looper.loop(Looper.java:224)
at android.app.ActivityThread.main(ActivityThread.java:7560)
at java.lang.reflect.Method.invoke(Native Method)
at com.android.internal.os.RuntimeInit$MethodAndArgsCaller.run(RuntimeInit.java:539)
at com.android.internal.os.ZygoteInit.main(ZygoteInit.java:950)
Gradle Version
8.11.1
AGP Version
8.7.3
Code Minifier/Optimizer
None
Version
4.14.1
Sentry SDK Version
7.18.0
Steps to Reproduce
Use the Sentry auto-init feature:
4.14.1AndroidManifest.xml:<meta-data android:name="io.sentry.traces.sample-rate" android:value="1.0" />The issue started from
4.14.0. The version4.13.0is working as expected. This PR is probably the cause of the issue.Expected Result
Successfully init the App with the Sentry configuration. The logcat will show only
io.sentry.auto-init read: truewhen filtering for "Sentry" word.Actual Result
The Logcat shows
io.sentry.auto-init read: trueand then warning messages related to the manifest configuration of float values: