@cpaulgilman

Description

@cpaulgilman

Defaults need updating

No default value found for 'compute_as_cube' in external file (Fuel Cell/Commercial), using internal default
No default value found for 'batt_unit_capacity' in external file (Fuel Cell/Commercial), using internal default
No default value found for 'batt_unit_surface_area' in external file (Fuel Cell/Commercial), using internal default

Default simulation fail. Fix by changing default dispatch from input battery power targets to peaks shaving or manual dispatch:

exec fail(battery): Invalid custom dispatch, must be 8760 * steps_per_hour.
Simulation battery failed :exec fail(battery): Invalid custom dispatch, must be 8760 * steps_per_hour.
monthly_grid_to_batt not assigned
Simulation cashloan failed :monthly_grid_to_batt not assigned

Grid outage and critical load inputs are available, but Outage Discharge Limits form is missing from Dispatch page. Should it be added?