Describe the bug
I have a custom weather file with measured POA data. If I use the heat transfer method (CEC module model) for temperature, cell temperature is being calculated as equal to ambient temperature.
Expected behavior
I would expect cell temperature to be different from ambient temperature in most daytime hours.
Screenshots


Operating System and Version
- OS: Windows
- Version: SAM 2022.11.21 r3
Additional context
Temperature seems ok when using the NOCT method.
Describe the bug
I have a custom weather file with measured POA data. If I use the heat transfer method (CEC module model) for temperature, cell temperature is being calculated as equal to ambient temperature.
Expected behavior
I would expect cell temperature to be different from ambient temperature in most daytime hours.
Screenshots
Operating System and Version
Additional context
Temperature seems ok when using the NOCT method.