Skip to content

Incorrect Coil Sizing Report for Coil:Heating:Gas:MultiStage #11062

@amirroth

Description

@amirroth

Issue overview

For this type of coil, data from the ReportCoilSelection object was ignored because the coil "ModelType" was set as "GasMultistage" rather than "Gas:MultiStage" and "Coil:Heating:GasMultistage" is not a valid coil type. Example from the testfile MultiSpeedACFurnace.idf.

Image

Note the missing fields for HVAC Type, HVAC Name, and Total and Sensible Capacity for HEAT PUMP HEATING COIL 1. Here are the fields when "ModelType" is changed to "Gas:MultiStage".

Image

A similar problem occurs for th "Coil:Heating:Electric:MultiStage" in several other test files.

Operating System (Multiple choices)

Any

Operating System Version

Any

Version of EnergyPlus

25.1.0

Unmethours link or helpdesk ticket number

N/A

Defect file

This occurs the testfile MultiStageACFurnace.idf.