Skip to content

Incorperate inverter losses into grid limits code#1277

Merged
brtietz merged 1 commit into
patchfrom
sam_1982_fix_batt_grid_limits
Feb 21, 2025
Merged

Incorperate inverter losses into grid limits code#1277
brtietz merged 1 commit into
patchfrom
sam_1982_fix_batt_grid_limits

Conversation

@brtietz

@brtietz brtietz commented Feb 14, 2025

Copy link
Copy Markdown
Collaborator

The previous grid limits code did not properly account for inverter night time losses, this code corrects that issue.

Note that there are still some issues with power to grid below 10% battery SOC. Those might be better solved as a part of #1202

Fixes NatLabRockies/SAM#1982

@brtietz brtietz added this to the 2024 Release Patch 1 milestone Feb 14, 2025
@brtietz brtietz requested a review from cpaulgilman February 14, 2025 22:09

@cpaulgilman cpaulgilman left a comment

Copy link
Copy Markdown
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Looks good, thanks for fixing.

@brtietz brtietz merged commit f248f82 into patch Feb 21, 2025
@brtietz brtietz modified the milestones: 2024 Release Patch 1, SAM Spring 2025 Release Mar 7, 2025
@brtietz brtietz deleted the sam_1982_fix_batt_grid_limits branch April 18, 2025 22:23