Description
Issue overview
Testing shows that UnitarySystem does not report the DX Coil Capacity Increase/Decrease Ratio from Too Low/High Flow/Capacity Ratio. This happens when UnitarySystem calls for cooling capacity before the coil is modeled. The flow/capacity is adjusted on this call and the subsequent call to the coil model uses the corrected capacity.
Details
Some additional details for this issue (if relevant):
- Platform (Operating system, version)
- Version of EnergyPlus (if using an intermediate build, include SHA)
- Unmethours link or helpdesk ticket number
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.
- Defect file added (2ZoneDataCenterHVAC_wEconomizer need to change CoilSystem to UnitarySystem)
- Ticket added to Pivotal for defect (development team task)
- Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)