I/O Ref should indicate which output variables are only available for interior or exterior windows #4306

@BobHenninger

Description

@BobHenninger

User has qustions about output variables from DSF; Double Skin Facade modeling. He ahd include the following output:variable objects ; Window Convection Heat Gain from Glazing to Zone, Window Net Infrared Heat Gain from Glazing to Zone, Window Heat Gain from Frame and Divider to Zone, and Window Frame Heat Gain however, the outputs did not show up even though the RDD has them.

MJW response to user follows:
Not all output variables are available for interior windows. I see that the Input Output Reference does not state this clearly. The attached rdd file shows the variables which are available for interior windows (created by deleting the exterior windows from your idf, and all airflownetwork objects).

Helpdesk Ticket 6665

Heat Gain Test-DSF-year sim_C-C-C-C-Outter Single C 12mm-ds.idf
Heat Gain Test-DSF-year sim_C-C-C-C-Outter Single C 12mm-ds-1week-Stars-OnlyInteriorWindows.rdd

Metadata

Metadata

Assignees

No one assigned

    Labels

    DocumentationRelated primarily on the LaTeX-based EnergyPlus documentationSeverityLowThis defect is low severity, generally indicating low impact with a workaround available