Incorrect accounting for zone multipliers in the Outdoor Air Details report #10799

@mdahlhausen

Description

@mdahlhausen

Issue overview

When zone multipliers are used with zone multipliers, incorrect values show up in the Mechanical Ventilation Parameters by Zone table in the Outdoor Air Details Report. This may only be occurring for some, not all system types.

In this example model DOAS_WSHP_multipliers.zip, CORE_MID ZN (and other MID zones) have a zone multiplier of 10. CORE_MID ZN has the same load assumptions as CORE_BOTTOM ZN and CORE_TOP ZN. CORE_BOTTOM ZN and CORE_TOP ZN have a zone multiplier of 1.

image

Average Number of Occupants,Nominal Number of Occupants,Zone Volume [m3], and Zone Area are the same for all CORE zones. Design Zone Outdoor Airflow - Voz [m3/s] and Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] are different, apparently already accounting for the zone multiplier. In the Total Facility line, the MID zone multipliers are applied again to calculate the total, giving incorrect totals for Design Zone Outdoor Airflow - Voz [m3/s] and Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]. The code here fails to account for the zone multipliers already being included in the total.

Details

  • EnergyPlus 24.1

Checklist

Add to this list or remove from it as applicable. This is a simple templated set of guidelines.

  • Defect file added (defect file here).
  • Ticket added to EnergyPlus Defect Complexity (Github Project)
  • Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)