Apps112

APLUSA Stats 3.0.2 - App Store




About APLUSA Stats

3 common statistical tools used to analyze market research results: 1 - CONFIDENCE INTERVAL CALCULATOR 2 - COMPARING TWO PERCENTAGES 3 - SAMPLE SIZE CALCULATOR ----------------------------------------- 1 - CONFIDENCE...

3 common statistical tools used to analyze market research results: 1 - CONFIDENCE INTERVAL CALCULATOR 2 - COMPARING TWO PERCENTAGES 3 - SAMPLE SIZE CALCULATOR ----------------------------------------- 1 - CONFIDENCE INTERVAL CALCULATOR Level of accuracy in percentages observed: To conduct market research is to interview (or observe) a sample of individuals. The larger the sample, the greater the statistical accuracy. Confidence interval provides the level of accuracy of a given measure. FOR INSTANCE Upon interviewing a sample of 500 GP’s, 20% are found to be using Product A. So, what is, within the total population, the actual proportion of users of Product A. Assuming 5% risk level*, confidence interval is: . 20% +/-3.5 . [16.5%-23.5%] In other words, there is a 95% probability that the actual percentage of Product A users in the total population of GPs is between 16.5% and 23.5%. ------------------------------------- 2 - COMPARING TWO PERCENTAGES Statistical significance between 2 observed percentages: When comparing opinions (or attitudes) measured on two samples, a significance test is applied. Significance tests provide an indication whether observed percentages are significantly different or not. FOR INSTANCE Upon interviewing a sample of 500 GP’s, 20% are found to be using Product A. Equally, upon interviewing a sample of 150 cardiologists, 25% of those are found to be using Product A. Would such a result suggest that a larger proportion of cardiologists is using Product A? At 5% risk level*, the two percentages observed on these samples are not statistically different. In other words, there is a 95% probability that the actual proportion of Product A users among GPs’ total population is similar to the actual proportion of Product A users among cardiologists’ total population. ------------------------------- 3 - SAMPLE SIZE CALCULATOR Minimum sample size calculations: By taking into account an expected percentage, as well as the corresponding confidence interval, it is possible to calculate the sample size needed for a given market research survey. This application calculates the minimum sample of respondents needed in order to achieve the required level of research accuracy. FOR INSTANCE Research is needed to evaluate the level of use of Product A among anaesthetists. The desired confidence interval is +/-8. Approximately one third of anaesthetists is expected to be using Product A. How many anaesthetists need to be interviewed in order to achieve this margin of error? At 5% risk level*, for an expected percentage of 33%, with a confidence interval of +/-8, minimum sample size is 133 anesthetists. In other words, if you interview a minimum of 133 anesthetists, there is a 95% chance to get a confidence interval of +/-8 if the proportion of Product A users in the anesthetist sample is 33%.

Version History “About” section: reinstated the charts from the previous version to make example interpretation easier. “Sample” page: replaced the placeholder text “CI” with “Confidence Interval” for improved clarity. Tablet layout – “Contact” page: improved display with a more compact arrangement of agencies and locations. Updated store screenshots to reflect the latest changes in the app. 3.0.2 10/19/2025 Interface modification Internationalization implementation Comparison fix 3.0.1 09/09/2025 Information updated relating to age classification 3.0.0 09/04/2025 Changed the subtitle for the French version 2.3.4 08/11/2022 Changing of the app icon. 2.3.3 08/02/2022 Removed the registration/login step, fixed various bugs and updated contact details 2.3.2 07/21/2022 Bug fixes related to user experience in login screen 2.3.1 03/19/2020 Correction of texts and coordinates. 2.3 02/19/2020 This update brings graphic corrections as well as the update of our coordinates. 2.2 01/28/2020 - Bug fixes and improvements. 2.1 12/06/2018 iOS 12 compatibility. All new Design. Notifications add New 'Publications' page added: be informed of all publications of AplusA. 2.0 10/11/2018 A reset button is added to numeric keypad, as well as contact details for A+A New York office. 1.1 02/17/2011 Bug fixes 1.0.1 01/04/2011 1.0 12/28/2010



Previous Versions

Here you can find the changelog of APLUSA Stats since it was posted on our website on 2023-07-04 10:43:44. The latest version is 3.0.2 and it was updated on 2026-06-10 23:29:39. See below the changes in each version.

APLUSA Stats version 3.0.2
Updated At: 2026-06-10
Changes: Version History “About” section: reinstated the charts from the previous version to make example interpretation easier. “Sample” page: replaced the placeholder text “CI” with “Confidence Interval” for improved clarity. Tablet layout – “Contact” page: improved display with a more compact arrangement of agencies and locations. Updated store screenshots to reflect the latest changes in the app. 3.0.2 10/19/2025 Interface modification Internationalization implementation Comparison fix 3.0.1 09/09/2025 Information updated relating to age classification 3.0.0 09/04/2025 Changed the subtitle for the French version 2.3.4 08/11/2022 Changing of the app icon. 2.3.3 08/02/2022 Removed the registration/login step, fixed various bugs and updated contact details 2.3.2 07/21/2022 Bug fixes related to user experience in login screen 2.3.1 03/19/2020 Correction of texts and coordinates. 2.3 02/19/2020 This update brings graphic corrections as well as the update of our coordinates. 2.2 01/28/2020 - Bug fixes and improvements. 2.1 12/06/2018 iOS 12 compatibility. All new Design. Notifications add New 'Publications' page added: be informed of all publications of AplusA. 2.0 10/11/2018 A reset button is added to numeric keypad, as well as contact details for A+A New York office. 1.1 02/17/2011 Bug fixes 1.0.1 01/04/2011 1.0 12/28/2010
APLUSA Stats version 3.0.2
Updated At: 2025-10-19
Changes: “About” section: reinstated the charts from the previous version to make example interpretation easier. “Sample” page: replaced the placeholder text “CI” with “Confidence Interval” for improved clarity. Tablet layout – “Contact” page: improved display with a more compact arrangement of agencies and locations. Updated store screenshots to reflect the latest changes in the app.
APLUSA Stats version 3.0.1
Updated At: 2025-09-09
Changes: Sep 9, 2025 Version 3.0.1 Interface modification Internationalization implementation Comparison fix
APLUSA Stats version 2.3.4
Updated At: 2022-08-11
Changes: Aug 11, 2022 Version 2.3.4 Changed the subtitle for the French version


Related Apps

Here you can find apps that are similar with APLUSA Stats.



Disclaimer

Official App Store Link


We do not host APLUSA Stats on our servers. We did not scan it for viruses, adware, spyware or other type of malware. This app is hosted by Apple and passed their terms and conditions to be listed there. We recommend caution when installing it.

The App Store link for APLUSA Stats is provided to you by apps112.com without any warranties, representations or guarantees of any kind, so access it at your own risk.

If you have questions regarding this particular app contact the publisher directly. For questions about the functionalities of apps112.com contact us.

BarCode2D-PNG


Click stars to rate this APP!

Users Rating:  
  0.0/5     0
Downloads: 34
Updated At: 2026-06-10 23:29:39
Publisher: A PLUS A SAS
Operating System: IOS
License Type: Free