{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T23:58:14Z","timestamp":1769212694267,"version":"3.49.0"},"reference-count":43,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2010,3,16]],"date-time":"2010-03-16T00:00:00Z","timestamp":1268697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a two stage algorithm for real-time estimation of instantaneous tremor parameters from gyroscope recordings. Gyroscopes possess the advantage of providing directly joint rotational speed, overcoming the limitations of traditional tremor recording based on accelerometers. The proposed algorithm first extracts tremor patterns from raw angular data, and afterwards estimates its instantaneous amplitude and frequency. Real-time separation of voluntary and tremorous motion relies on their different frequency contents, whereas tremor modelling is based on an adaptive LMS algorithm and a Kalman filter. Tremor parameters will be employed to drive a neuroprosthesis for tremor suppression based on biomechanical loading.<\/jats:p>","DOI":"10.3390\/s100302129","type":"journal-article","created":{"date-parts":[[2010,3,16]],"date-time":"2010-03-16T14:30:07Z","timestamp":1268749807000},"page":"2129-2149","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":89,"title":["Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data"],"prefix":"10.3390","volume":"10","author":[{"given":"Juan","family":"Gallego","sequence":"first","affiliation":[{"name":"Bioengineering Group, Consejo Superior de Investigaciones Cient\u00edficas, CSIC, Ctra. Campo Real, km 0.2 La Poveda, 28500, Arganda del Rey, Spain"}]},{"given":"Eduardo","family":"Rocon","sequence":"additional","affiliation":[{"name":"Bioengineering Group, Consejo Superior de Investigaciones Cient\u00edficas, CSIC, Ctra. Campo Real, km 0.2 La Poveda, 28500, Arganda del Rey, Spain"}]},{"given":"Javier O.","family":"Roa","sequence":"additional","affiliation":[{"name":"Bioengineering Group, Consejo Superior de Investigaciones Cient\u00edficas, CSIC, Ctra. Campo Real, km 0.2 La Poveda, 28500, Arganda del Rey, Spain"}]},{"given":"Juan","family":"Moreno","sequence":"additional","affiliation":[{"name":"Bioengineering Group, Consejo Superior de Investigaciones Cient\u00edficas, CSIC, Ctra. Campo Real, km 0.2 La Poveda, 28500, Arganda del Rey, Spain"}]},{"given":"Jos\u00e9 L.","family":"Pons","sequence":"additional","affiliation":[{"name":"Bioengineering Group, Consejo Superior de Investigaciones Cient\u00edficas, CSIC, Ctra. Campo Real, km 0.2 La Poveda, 28500, Arganda del Rey, Spain"}]}],"member":"1968","published-online":{"date-parts":[[2010,3,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1002\/mus.1063","article-title":"The pathophysiology of tremor","volume":"24","author":"Deuschl","year":"2001","journal-title":"Muscle Ner"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3","DOI":"10.3233\/TAD-2004-16102","article-title":"Pathological tremor management: Modelling, compensatory technology and evaluation","volume":"16","author":"Rocon","year":"2004","journal-title":"Technol. Disabil"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/mds.870131303","article-title":"Consensus statement of the movement disorder society on tremor. Ad hoc scientific committee","volume":"13","author":"Deuschl","year":"1998","journal-title":"Mov. Disord"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1002\/mds.20231","article-title":"Effect of stimulation frequency on tremor suppression in essential tremor","volume":"19","author":"Ushe","year":"2004","journal-title":"Mov. Disord"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2170","DOI":"10.1212\/01.WNL.0000145603.48221.B5","article-title":"Suicide after successful deep brain stimulation for movement disorders","volume":"63","author":"Burkhard","year":"2004","journal-title":"Neurology"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1152\/jappl.1967.23.3.324","article-title":"Mechanical factors in human tremor frequency","volume":"23","author":"Stiles","year":"1967","journal-title":"J. Appl. Physiol"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1113\/jphysiol.1974.sp010615","article-title":"The effects of load and force on tremor at the normal human elbow joint","volume":"240","author":"Joyce","year":"1974","journal-title":"J. Physiol"},{"key":"ref_8","unstructured":"Adelstein, B.D. (Peripheral Mechanical Loading and the Mechanism of Abnormal Intention Tremor, 1981). Peripheral Mechanical Loading and the Mechanism of Abnormal Intention Tremor, Master\u2019s Thesis;."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1109\/TNSRE.2007.903917","article-title":"Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression","volume":"15","author":"Rocon","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehab. Eng"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Popovic, D., and Sinkjaer, T. (2000). Control of Movement for the Physically Disabled, Springer.","DOI":"10.1007\/978-1-4471-0433-9"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/S0003-9993(99)90141-7","article-title":"Clinical evaluation of the bionic glove","volume":"80","author":"Popovic","year":"1999","journal-title":"Arch. Phys. Med. Rehabil"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/S0021-9290(01)00231-7","article-title":"Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems","volume":"35","author":"Mayagoitia","year":"2002","journal-title":"J. Biomech"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Pons, J.L. (2008). Wearable Robots: Biomechatronic Exoskeletons, John Wiley & Sons.","DOI":"10.1002\/9780470987667"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1109\/TITB.2008.2006403","article-title":"Extraction of sources of tremor in hand movements of patients with movement disorders","volume":"13","author":"Vinjamuri","year":"2009","journal-title":"IEEE Trans. Inform. Tech. Biomed"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0165-0270(90)90140-B","article-title":"Quantification of tremor with a digitizing tablet","volume":"32","author":"Elble","year":"1990","journal-title":"J. Neurosci. Meth"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1109\/10.686791","article-title":"Adaptive canceling of physiological tremor for improved precision in microsurgery","volume":"45","author":"Riviere","year":"1998","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Veluvolu, K.C., Tan, U.X., Latt, W.T., Shee, C.Y., and Ang, W.T. (2007, January August). Bandlimited Multiple Fourier Linear Combiner for real-time tremor compensation. Kiel, Germany.","DOI":"10.1109\/IEMBS.2007.4352922"},{"key":"ref_18","unstructured":"Elble, R.J., and Koller, W.C. (1990). Tremor, The John Hopkins Univesity Press."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Grimaldi, G., and Manto, M. (2008). Tremor from Pathogenesis to Treatment, Morgan & Claypool.","DOI":"10.1007\/978-3-031-01627-1"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Rocon, E., Moreno, J.C., Ruiz, A.F., Brunetti, F., Miranda, J.A., and Pons, J.L. (2007, January June). Application of inertial sensors in rehabilitation robotics. Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428420"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/BF02345966","article-title":"Measuring orientation of human body segments using miniature gyroscopes and accelerometers","volume":"43","author":"Luinge","year":"2005","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1109\/TNSRE.2005.847353","article-title":"Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation","volume":"13","author":"Roetenberg","year":"2005","journal-title":"IEEE Trans. Neural Syst. Rehab. Eng"},{"key":"ref_23","unstructured":"Harada, T., Uchino, H., Mori, T., and Sato, T. (1,, January July). Portable orientation estimation device based on accelerometers, magnetometers and gyroscope sensors for sensor network. Tokyo, Japan."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1007\/s11517-006-0065-x","article-title":"Empirical Mode Decomposition: a novel technique for the study of tremor time series","volume":"44","author":"Rocon","year":"2006","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.ncl.2009.04.003","article-title":"Tremor: clinical features, pathophysiology, and treatment","volume":"27","author":"Elble","year":"2009","journal-title":"Neurologic. Clin"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.bspc.2009.06.001","article-title":"Double adaptive bandlimited multiple Fourier linear combiner for real-time estimation\/filtering of physiological tremor","volume":"5","author":"Veluvolu","year":"2010","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"B\u00f3, A.P.L., Poignet, P., and Geny, C. (2009, January October). Filtering voluntary motion for pathological tremor compensation. St. Louis, MO, USA.","DOI":"10.1109\/IROS.2009.5353972"},{"key":"ref_28","first-page":"373","article-title":"A wearable tremor-suppression orthosis","volume":"35","author":"Kotovsky","year":"1998","journal-title":"J. Rehabil. Res. Dev"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/S1350-4533(99)00030-2","article-title":"A practical gait analysis system using gyroscopes","volume":"21","author":"Tong","year":"1999","journal-title":"Med. Eng. Phys"},{"key":"ref_30","unstructured":"Fahn, S., Tolosa, E., and Marin, C. (1998). Parkinson\u2019s Disease and Movement Disorders, Urban & Schwarzenberg."},{"key":"ref_31","unstructured":"Belda-Lois, J.M., Rocon, E., S\u00e1nchez-Lacuesta, J.J., Ruiz, A.F., and Pons, J.L. (2005, January September). Functional assessment of tremor in the upper limb. Lille, France."},{"key":"ref_32","first-page":"99","article-title":"Evaluating manual control devices for those with tremor disability","volume":"24","author":"Riley","year":"1987","journal-title":"J. Rehabil. Rese. Dev"},{"key":"ref_33","unstructured":"Riviere, C.N. (Adaptive Suppression of Tremor for Improved Human Machine Control, 1981). Adaptive Suppression of Tremor for Improved Human Machine Control, PhD Thesis;."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1002\/jor.1100070219","article-title":"Frequency spectrum analysis of wrist motion for activities of daily living","volume":"7","author":"Mann","year":"1989","journal-title":"J. Orthop. Res"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1109\/PROC.1975.10036","article-title":"Adaptive noise canceling: Principles and applications","volume":"63","author":"Widrow","year":"1975","journal-title":"Proc. IEEE"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Brookner, E. (1998). Tracking and Kalman Filtering Made Easy, John Wiley & Sons.","DOI":"10.1002\/0471224197"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1109\/TAC.1962.1105477","article-title":"Synthesis of an optimal track-while-scan smoothing equations","volume":"7","author":"Benedict","year":"1962","journal-title":"IRE Trans. Automat. Control"},{"key":"ref_38","unstructured":"Bar-Shalom, Y., and Li, X.R. (1998). Estimation and Tracking: Principles, Techniques and Software, Artech House Publishers."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1093\/brain\/121.11.2127","article-title":"Time-frequency analysis of tremors","volume":"121","author":"Matsumoto","year":"1998","journal-title":"Brain"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/78.258116","article-title":"An adaptive estimation of periodic signals using a Fourier linear combiner","volume":"42","author":"Vaz","year":"1994","journal-title":"IEEE Trans. Signal Process"},{"key":"ref_41","unstructured":"Rocon, E. (Reducci\u00f3n Activa de Temblor Patol\u00f3gico de Miembro Superior Mediante Exoesqueletos Rob\u00f3ticos, 2006). Reducci\u00f3n Activa de Temblor Patol\u00f3gico de Miembro Superior Mediante Exoesqueletos Rob\u00f3ticos, PhD Thesis;."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1109\/10.841338","article-title":"Optimal digital filtering for tremor suppression","volume":"47","author":"Gonzalez","year":"2000","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1109\/TASSP.1981.1163568","article-title":"Adaptive estimation of time delays in sampled data systems","volume":"29","author":"Etter","year":"1981","journal-title":"IEEE Trans. Acoust. Speech Signal Process"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/3\/2129\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:01:47Z","timestamp":1760220107000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/10\/3\/2129"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,3,16]]},"references-count":43,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2010,3]]}},"alternative-id":["s100302129"],"URL":"https:\/\/doi.org\/10.3390\/s100302129","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3,16]]}}}